Wissenschaftliche Artikel

Malec, A., Kokkinis, G., Haiden, C., & Giouroudi, I. (2018). Biosensing System for Concentration Quantification of Magnetically Labeled E. coli in Water Samples. Sensors, 18(7), 2250. https://doi.org/10.3390/s18072250 ( reposiTUm)
Giouroudi, I., & Hristoforou, E. (2018). Perspective: Magnetoresistive sensors for Biomedicine. Journal of Applied Physics, 124(3), 030902. https://doi.org/10.1063/1.5027035 ( reposiTUm)
Kashanian, F., Kokkinis, G., Bernardi, J., Zand, M. R., Shamloo, A., & Giouroudi, I. (2018). A novel magnetic microfluidic platform for on-chip separation of 3 types of silica coated magnetic nanoparticles (Fe₃O₄@SiO₂). Sensors and Actuators A: Physical, 270, 223–230. https://doi.org/10.1016/j.sna.2017.12.047 ( reposiTUm)
Kokkinis, G., Cardoso, S. F., Keplinger, F., & Giouroudi, I. (2017). Microfluidic platform with integrated GMR sensors for quantification of cancer cells. Sensors and Actuators B: Chemical, 241, 438–445. http://hdl.handle.net/20.500.12708/146264 ( reposiTUm)
Giouroudi, I., & Kokkinis, G. (2017). Recent advances in magnetic microfluidic biosensors. Journal of Nanomaterials, 7(7), 171. https://doi.org/10.3390/nano7070171 ( reposiTUm)
Jamalieh, M., Kokkinis, G., Haiden, C., Berris, T., Keplinger, F., & Giouroudi, I. (2016). Microfluidic platform for pathogen load monitoring. Microelectronic Engineering, 158, 91–94. https://doi.org/10.1016/j.mee.2016.03.004 ( reposiTUm)
Kokkinis, G., Plochberger, B., Cardoso, S. F., Keplinger, F., & Giouroudi, I. (2016). Microfluidic, dual-purpose sensor for in-vitro detection of Enterobacteriaceae and biotinylated antibodies. Lab on a Chip, 1, 12. http://hdl.handle.net/20.500.12708/148207 ( reposiTUm)
Kokkinis, G., Plochberger, B., Cardoso, S., Keplinger, F., & Giouroudi-Jovanovic, I. (2016). A microfluidic, dual-purpose sensor for in vitro detection of Enterobacteriaceae and biotinylated antibodies. Lab on a Chip, 16, 1261–1271. https://doi.org/10.1039/C6LC00008H ( reposiTUm)
Devkota, J., Kokkinis, G., Berris, T., Jamalieh, M. A., Cardoso, S. F., Cardoso, F. A., Srikanth, H., Phan, M. H., & Giouroudi, I. (2015). A novel approach for detection and quantification of magnetic nanomarkers using a spin valve GMR-integrated microfluidic sensor. RSC Advances, 5(63), 51169–51175. https://doi.org/10.1039/c5ra09365a ( reposiTUm)
Kokkinis, G., Jamalieh, M. A., Cardoso, F. A., Cardoso, S., Keplinger, F., & Giouroudi, I. (2015). Magnetic based Biomolecule Detection using GMR Sensors. Journal of Applied Physics, 117(17), 17B731. https://doi.org/10.1063/1.4917244 ( reposiTUm)
Kokkinis, G., Cardoso, S. F., Arroyo Cardoso, F., & Giouroudi, I. (2014). Microfluidics for the Rapid Detection of Pathogens Using Giant Magnetoresistance Sensors. IEEE Transactions on Magnetics, 50(11), 44013041–44013044. http://hdl.handle.net/20.500.12708/157753 ( reposiTUm)
Giouroudi, I., Gooneratne, C., & Kokkinis, G. (2014). Controlled trapping and detection of magnetic particles by a magnetic microactuator and a giant magnetoresistance (GMR) sensor. Key Engineering Materials, 605, 352–355. https://doi.org/10.4028/www.scientific.net/kem.605.352 ( reposiTUm)
Kokkinis, G., Dangl, A., Keplinger, F., & Giouroudi, I. (2014). Microfluidic biosensing method using the motion of magnetic microparticles. Key Engineering Materials, 605, 348–351. https://doi.org/10.4028/www.scientific.net/kem.605.348 ( reposiTUm)
Giouroudi, I., Kokkinis, G., Fodil, K., Denoual, M., Dolabdjian, C., Madtha, S., Torabi-Makhsos, E., & Keplinger, F. (2014). On-Chip Separation and Detection of Magnetically Labeled Pathogens. J Nanomed Nanotechnol, 5(5), 225. http://hdl.handle.net/20.500.12708/157757 ( reposiTUm)
Kokkinis, G., Keplinger, F., & Giouroudi, I. (2013). On-chip microfluidic biosensor using superparamagnetic microparticles. Biomicrofluidics, 7(5), 054117. https://doi.org/10.1063/1.4826546 ( reposiTUm)
Gooneratne, C., Yassine, O., Giouroudi, I., & Kosel, J. (2013). Selective Manipulation of Superparamagnetic Beads by a Magnetic Microchip. IEEE Transactions on Magnetics, 49(7), 3418–3421. http://hdl.handle.net/20.500.12708/155100 ( reposiTUm)
Giouroudi, I., & Keplinger, F. (2013). Microfluidic Biosensing Systems Using Magnetic Nanoparticles. International Journal of Molecular Sciences, 14(9), 18535–18556. https://doi.org/10.3390/ijms140918535 ( reposiTUm)
Gooneratne, C. P., Giouroudi, I., & Kosel, J. (2012). A Planar Conducting Micro-Loop Structure for Transportation of Magnetic Beads: An Approach towards Rapid Sensing and Quantification of Biological Entities. Sensor Letters, 10(3), 770–774. https://doi.org/10.1166/sl.2012.2583 ( reposiTUm)
Li, B., Salem, N. P. M. H., Giouroudi, I., & Kosel, J. (2012). Integration of thin film giant magnetoimpedance sensor and surface acoustic wave transponder. Journal of Applied Physics, 111(7), 07E514. https://doi.org/10.1063/1.3678439 ( reposiTUm)
Gooneratne, C. P., Liang, C., Giouroudi, I., & Kosel, J. (2012). An integrated micro-chip for rapid detection of magnetic particles. Journal of Applied Physics, 111(7), 07B327. https://doi.org/10.1063/1.3678303 ( reposiTUm)
Li, F., Giouroudi, I., & Kosel, J. (2012). A biodetection method using magnetic particles and micro traps. Journal of Applied Physics, 111(7), 07B328. https://doi.org/10.1063/1.3678304 ( reposiTUm)
Giouroudi, I., van den Driesche, S., Kosel, J., Grössinger, R., & Vellekoop, M. J. (2011). On-chip bio-analyte detection utilizing the velocity of magnetic microparticles in a fluid. Japanese Journal of Applied Physics, 109(7), 07B304. https://doi.org/10.1063/1.3556952 ( reposiTUm)
Gooneratne, C. P., Giouroudi, I., Liang, C., & Kosel, J. (2011). A giant magnetoresistance ring-sensor based microsystem for magnetic bead manipulation and detection. Japanese Journal of Applied Physics, 109(7), 07E517. https://doi.org/10.1063/1.3536822 ( reposiTUm)
Giouroudi, I., & Kosel, J. (2010). Recent Progress in Biomedical Applications of Magnetic Nanoparticles. Recent Patents on Nanotechnology, 4, 111–118. http://hdl.handle.net/20.500.12708/167227 ( reposiTUm)
Cvetanovic, A., Cvetanovic, A., Deutschinger, A., Giouroudi, I., & Brenner, W. (2009). Design of a novel visual and control system for the prevention of the collision during the micro handling in a SEM chamber. Microelectronic Engineering, 87(2), 139–143. https://doi.org/10.1016/j.mee.2009.06.031 ( reposiTUm)
Adamovic, N., Giouroudi, I., Matovic, J., Djinovic, Z., & Schmid, U. (2009). Microactuators for Fluidic Applications: Principles, Devices and Systems. Journal of Microelectronics and Electronic Packaging, 6(4), 250–264. http://hdl.handle.net/20.500.12708/167529 ( reposiTUm)
Traxler, S., Kosel, J., Pfützner, H., Kaniusas, E., Mehnen, L., & Giouroudi, I. (2008). Contactless dlow detection with magnetostrictive bilayers. Sensors and Actuators A: Physical, A 142/2, 491–495. http://hdl.handle.net/20.500.12708/168625 ( reposiTUm)
Giouroudi, I., Kosel, J., Pfützner, H., & Brenner, W. (2008). Magnetostrictive bilayer sensor system for testing of rotating microdevices. Sensors and Actuators A: Physical, 142, 474–478. http://hdl.handle.net/20.500.12708/171046 ( reposiTUm)
Cvetanovic, A., Cvetanovic, A., Andrijasevic, D., Giouroudi, I., & Brenner, W. (2008). Development of a novel protective cover for micro manipulation process in the SEM chamber. Microsystem Technologies, 14(8), 1143–1148. https://doi.org/10.1007/s00542-008-0609-0 ( reposiTUm)
Giouroudi, I., Hötzendorfer, H., Kosel, J., Andrijasevic, D., & Brenner, W. (2007). Development of a microgripping system for handling of microcomponents. Precision Engineering, 32(2), 148–152. https://doi.org/10.1016/j.precisioneng.2007.07.002 ( reposiTUm)
Hauser, H., Giouroudi, I., Steurer, J., Musiejovsky, L., & Nicolics, J. (2007). Magnetic Hysteresis Modeling of Thin Film Giant Magnetoimpedance Sensors. Sensor Letters, 5(1), 133–137. http://hdl.handle.net/20.500.12708/168599 ( reposiTUm)
Nicolics, J., Musiejovsky, L., Steurer, J., Giouroudi, I., Hauser, H., Mündlein, M., Zoppel, S., & Zehetner, J. (2007). Laser Welding Process Optimization for the Production of Giant Magnetoimpedance Magnetic Field Sensors. Sensor Letters, 5(1), 204–207. http://hdl.handle.net/20.500.12708/168630 ( reposiTUm)
Andrijasevic, D., Giouroudi, I., Smetana, W., Boehm, S., Zehetner, J., & Brenner, W. (2006). New approach to micro-joining by hot gas stream. Microelectronic Engineering, 83(4–9), 1445–1448. http://hdl.handle.net/20.500.12708/171806 ( reposiTUm)
Hauser, H., Steurer, J., Nicolics, J., & Giouroudi, I. (2006). Wireless Magnetic Field Sensor. Journal of Electrical Engineering, 57(12), 9–14. http://hdl.handle.net/20.500.12708/171826 ( reposiTUm)
Giouroudi, I., Hauser, H., Musiejovsky, L., & Steurer, J. (2006). Giant magnetoimpedance sensor integrated in an oscillator system. Journal of Applied Physics, 99, 08D906-1-08D906-3. http://hdl.handle.net/20.500.12708/171799 ( reposiTUm)
Giouroudi, I., Hauser, H., Musiejovsky, L., & Steurer, J. (2006). Characterization of Amorphous GMI Thin-Film Meander Trilayers. IEEE Sensors Journal, 6(4), 970–973. http://hdl.handle.net/20.500.12708/171802 ( reposiTUm)
Giouroudi, I., Hauser, H., Musiejovsky, L., Steurer, J., & Didosyan, Y. S. (2005). Investigation of magnetoimpedance effect in amorphous thin-film microstructures. Journal of Applied Physics, 97(10M109), 1–3. http://hdl.handle.net/20.500.12708/171515 ( reposiTUm)

Beiträge in Tagungsbänden

Malec, A., Kokkinis, G., Haiden, C., Bajac, B., & Giouroudi, I. (2018). Magnetic Microfluidic Platform for E. Coli Detection in Water Samples. In Book of Abstracts EMSA 2018 (p. 1). http://hdl.handle.net/20.500.12708/76251 ( reposiTUm)
Managhebaty, M. A., Kokkinis, G., Malec, A., Haiden, C., Metzner, C., Jankovic, N., Gadjanski, I., Kitic, G., & Giouroudi, I. (2018). A novel microfluidic biosensing system for the detection of magnetically labelled FHV-1. In Proceedings Biosensors 2018 (p. 1). http://hdl.handle.net/20.500.12708/76250 ( reposiTUm)
Kokkinis, G., Cardoso, S., & Giouroudi, I. (2017). Microfluidic platform for detection and quantification of magnetic markers. In Proceedings SPIE 10247, Bio-MEMS and Medical Microdevices III (p. 4). http://hdl.handle.net/20.500.12708/76249 ( reposiTUm)
Malec, A., Haiden, C., Kokkinis, G., Keplinger, F., & Giouroudi, I. (2017). Dark field imaging system for size characterization of magnetic micromarkers. In SPIE Proceedings (pp. 102470B-1-102470B – 7). SPIE. http://hdl.handle.net/20.500.12708/76064 ( reposiTUm)
Kokkinis, G., & Giouroudi, I. (2016). Microfluidic Platform For Cell Membrane Deformation Utilizing Magnetic Particles. In Book of Abstract (p. 1). http://hdl.handle.net/20.500.12708/75412 ( reposiTUm)
Kokkinis, G., & Giouroudi, I. (2016). Magnetic Microfluidic Single Cell Trapping and Analysis Platform. In Book of Abstract - MNE 2016 (p. 165). http://hdl.handle.net/20.500.12708/75411 ( reposiTUm)
Giouroudi, I., Cardoso, S. F., & Kokkinis, G. (2016). Magnetic Microfluidic Biosensor for Rapid Biomolecule Quantification. In Book of Abstracts EMN 2016. EMN Hawaii Meeting, Hawaii, United States of America (the). http://hdl.handle.net/20.500.12708/75413 ( reposiTUm)
Kokkinis, G., Manh-Huong, P., Srikanth, H., Cardoso, S. F., & Giouroudi, I. (2016). Magnetic Microfluidic Biosensor for the Detection & Quantification of Biomolecules. In Proceedings of the 32nd Southern Biomedical Engineering Conference (p. 1). http://hdl.handle.net/20.500.12708/75409 ( reposiTUm)
Kokkinis, G., Cardoso, S. F., & Giouroudi, I. (2016). Biomedical applications of magnetic nanoparticles. In Book of Abstract - 11th EMSA (p. 1). http://hdl.handle.net/20.500.12708/75410 ( reposiTUm)
Stipsitz, M., Kokkinis, G., Gooneratne, C., Kosel, J., Cardoso, S. F., Cardoso, F., & Giouroudi, I. (2015). Magnetic Microfluidic Platform for Biomedical Applications using Magnetic Nanoparticles. In Proceedings of the 4th International Conference on Materials and Applications for Sensors and Transducers (pp. 207–210). Trans Tech Publications Ltd. https://doi.org/10.4028/www.scientific.net/kem.644.207 ( reposiTUm)
Jamalieh, M. A., Kokkinis, G., Haiden, C., Berris, T., Keplinger, F., & Giouroudi, I. (2015). Microfluidic Platform for Pathogen Load Monitoring. In Interactive Booklet MNE 2015 (p. 2). http://hdl.handle.net/20.500.12708/74891 ( reposiTUm)
Devkota, J., Kokkinis, G., Jamalieh, M. A., Phan, M. H., Skrikanth, H., Cardoso, S. F., Cardoso, F. A., & Giouroudi, I. (2015). GMR microfluidic biosensor for low concentration detection of Nanomag-D beads. In Proc. SPIE 9518, Bio-MEMS and Medical Microdevices II (p. 7). http://hdl.handle.net/20.500.12708/74726 ( reposiTUm)
Mitterböck, R. K., Kokkinis, G., Berris, T., Keplinger, F., & Giouroudi, I. (2015). Magnetic microfluidic system for isolation of single cells. In Proc. SPIE 9518, Bio-MEMS and Medical Microdevices II (p. 9). http://hdl.handle.net/20.500.12708/74725 ( reposiTUm)
Kokkinis, G., Jamalieh, M. A., Devkota, J., Cardoso, S. F., Srikanth, H., Manh-Huong, P., & Giouroudi, I. (2015). Detection and Quantification of Alginate Magnetic Nanoparticles on a Surface Modified Magnetoresistive Biosensor. In μTAS 2015 - Proceedings (pp. 1677–1679). http://hdl.handle.net/20.500.12708/74889 ( reposiTUm)
Giouroudi, I., Kokkinis, G., Fodil, K., Denoual, M., Dolabdjian, C., Madtha, S. A., Torabi-Makhsos, E., & Keplinger, F. (2014). On-Chip Separation and Detection of Magnetically Labeled Pathogens. In Proceedings (p. 1). http://hdl.handle.net/20.500.12708/74498 ( reposiTUm)
Kokkinis, G., Cardoso, S. F., Cardoso, F. A., & Giouroudi, I. (2014). Microfluidic Diagnostic System for the Rapid Detection of Pathogens using Giant Magnetoresistance Sensors. In Book of Abstracts (pp. 3388–3389). http://hdl.handle.net/20.500.12708/74497 ( reposiTUm)
Giouroudi, I. (2014). Microfluidic Biosensors using Magnetic Nanoparticles. In Book of Abstract (pp. 133–134). http://hdl.handle.net/20.500.12708/74496 ( reposiTUm)
Kokkinis, G., Jamalieh, M. A., Cardoso, F. A., Cardoso, S. F., Keplinger, F., & Giouroudi, I. (2014). Magnetic-Based Biomolucule Detection using GMR Sensors. In Abstracts (p. 422). http://hdl.handle.net/20.500.12708/74499 ( reposiTUm)
Gooneratne, C., Yassine, O., Giouroudi, I., & Kosel, J. (2013). Selective Manipulation of Superparamagnetic Beads by a Magnetic Microchip. In Conference Proceedings MMM 2013 (p. 2). http://hdl.handle.net/20.500.12708/73891 ( reposiTUm)
Giouroudi, I. (2013). Microfluidic biosensing system using the motion of magnetic nanoparticles. In Conference Proceedings EMN Fall 2013 (pp. 63–65). http://hdl.handle.net/20.500.12708/73657 ( reposiTUm)
Giouroudi, I., Kokkinis, G., Gooneratne, C., & Kosel, J. (2013). Microfluidic Biosensing Device for Controlled Trapping and Detection of Magnetic Microparticles. In 2013 29th Southern Biomedical Engineering Conference. 29th Southern Biomedical Engineering Conference, Miami, United States of America (the). https://doi.org/10.1109/sbec.2013.9 ( reposiTUm)
Dangl, A., Kokkinis, G., Keplinger, F., & Giouroudi, I. (2013). In vitro biosensing based on magnetically induced motion of magnetic nanoparticles. In Conference Proceedings (pp. 135–138). http://hdl.handle.net/20.500.12708/73446 ( reposiTUm)
Kokkinis, G., Keplinger, F., Kosel, J., & Giouroudi, I. (2013). On-chip biosensing utilizing the motion of suspended magnetic microparticles. In Book of Abstracts (p. 66). http://hdl.handle.net/20.500.12708/73444 ( reposiTUm)
Giouroudi, I., Alnassar, M., & Kosel, J. (2013). Fabrication and Properties of SmFe₂-PZT Magnetoelectric Thin Films. In Proceedings of SPIE - Smart Sensors, Actuators, and MEMS VI. SPIE Microtechnologies 2013, Grenoble, France. SPIE. https://doi.org/10.1117/12.2016769 ( reposiTUm)
Giouroudi, I., Kosel, J., Eftimiadis, K., Buttner, U., & Scheffer, C. (2012). Study of Cobalt-Platinum Thin Films grown by Pulsed Laser Deposition. In Advancements in Sensing Technology: New Developments and Practical Applications (pp. 769–773). Research Publishing. http://hdl.handle.net/20.500.12708/73147 ( reposiTUm)
Giouroudi, I., & Kosel, J. (2012). Biosensing based on Magnetically Induced Motion of Magnetic Particles. In ME Tagung 2012 (pp. 43–46). Schriftenreihe des Österreichischen Verbands für Elektrotechnik. http://hdl.handle.net/20.500.12708/73044 ( reposiTUm)
Giouroudi, I., Alnassar, M., Grössinger, R., & Kosel, J. (2012). Fabrication and Properties of CoFe2O4-PZT Magnetoelectric Thin Films. In Book of Abstract (p. 111). http://hdl.handle.net/20.500.12708/73043 ( reposiTUm)
Gooneratne, C., Giouroudi, I., & Kosel, J. (2011). A Novel Micro-Device for Long-Range Transportation of Magnetic Beads. In Book of Abstracts, 2-pages Digest INTERMAG 2011 (p. BW-03-1-BW-03-2). IEEE International Magnetics Conference. http://hdl.handle.net/20.500.12708/72201 ( reposiTUm)
Gooneratne, C. P., Liang, C., Giouroudi, I., & Kosel, J. (2011). A magnetic particle micro-trap for large trapping surfaces. In G. Kaltsas & C. Tsamis (Eds.), EurosensorsXXV (pp. 1201–1204). Elsevier BV. https://doi.org/10.1016/j.proeng.2011.12.296 ( reposiTUm)
Gooneratne, C., Liang, C., Giouroudi, I., & Kosel, J. (2011). A magnetic Bead Based Micro-Actuator for Manipulation of Cells in Low-Concentration Immunoassays. In Proceedings of the 37th Intern. Conference - MNE 2011 (pp. 547–548). http://hdl.handle.net/20.500.12708/72299 ( reposiTUm)
Salem, N. P. M. H., Li, B., Giouroudi, I., & Kosel, J. (2011). Integration of Thin Film Giant Magneto Impedance Sensor and Surface Acoustic Wave Transponder. In Conference Proceedings (p. 191). http://hdl.handle.net/20.500.12708/72576 ( reposiTUm)
Li, F., Giouroudi, I., Useinov, A., & Kosel, J. (2011). A new biodetection method using magnetic particles and magnetoresistive sensors. In Conference Proceedings (p. 595). http://hdl.handle.net/20.500.12708/72577 ( reposiTUm)
Gooneratne, C., Liang, C., Useinov, A., Giouroudi, I., & Kosel, J. (2011). A Half-Ring GMR Sensor for Detection of Magnetic Beads Immobilized On a Circular Micro-Trap. In Proceedings. 5th International Conference on Sensing Technology (ICST), Palmerston North, New Zealand. http://hdl.handle.net/20.500.12708/72573 ( reposiTUm)
Gooneratne, C., Liang, C., Giouroudi, I., & Kosel, J. (2011). A Highly Sensitive Integrated Micro-Device for Rapid Detection of Bacteria in Food. In Conference Proceedings (p. 595). http://hdl.handle.net/20.500.12708/72575 ( reposiTUm)
Gessesse, S., Giouroudi, I., & Kosel, J. (2011). Biosensing based on Magnetically Induced Motion of Superparamagnetic Beads. In Conference Proceedings (p. 191). http://hdl.handle.net/20.500.12708/72574 ( reposiTUm)
Giouroudi, I., Kosel, J., Büttner, U., Bucher, R., & Scheffer, C. (2010). Design of BioMEMS for HIV/AIDS Detection. In Proceedings of the ME 2010 (pp. 151–155). http://hdl.handle.net/20.500.12708/71441 ( reposiTUm)
Giouroudi, I., Kosel, J., & Scheffer, C. (2010). Lab-on-a-Chip System for Point-of-Care Diagnostics. In Book of Abstracts NANOSENS 2010. 3rd Conference Nanosensors for Industrial Applications - NANOSENS 2010, Vienna, Austria. http://hdl.handle.net/20.500.12708/71773 ( reposiTUm)
Giouroudi, I., Driesche, S. van den, & Kosel, J. (2010). Biosensing Utilizing the Motion of Magnetic Microparticles in a Microfluidic System. In B. Jakoby & M. J. Vellekoop (Eds.), Eurosensor XXIV Conference (pp. 824–827). Elsevier BV. https://doi.org/10.1016/j.proeng.2010.09.235 ( reposiTUm)
Giouroudi, I., Van den Driesche, S., Kosel, J., & Grössinger, R. (2010). On-Chip Pathogen Detection utilizing the Velocity of Magnetic Microparticles. In Book of Abstracts (p. 113). http://hdl.handle.net/20.500.12708/71775 ( reposiTUm)
Giouroudi, I., Kosel, J., Efthimiadis, K., Buttner, U., & Scheffer, C. (2010). Selective Attraction of Magnetic Beads for Biomems Utilizing CoPt Pulsed Laser deposited Thin Films. In Book of Abstracts (p. 6). http://hdl.handle.net/20.500.12708/71774 ( reposiTUm)
Brenner, W., Sümecz, F., Andrijasevic, D., Giouroudi, I., Malecki, K., & Almansa, A. (2007). ADVANCED METHODS AND TOOLS FOR HANDLING AND ASSEMBLY IN MICROTECHNOLOGY - A EUROPEAN APPROACH IN THE FRAME OF THE FP6 MARIE CURIE RESEARCH TRAINING NETWORK ASSEMIC. In 2nd Vienna International Conference on Micro- and Nano-Technology (pp. 55–62). http://hdl.handle.net/20.500.12708/70033 ( reposiTUm)
Hauser, H., Giouroudi, I., Nicolics, J., Ludwig, K., Rieder, G., Wecker, J., & Daalmans, G. (2007). Magnetoimpedance effect in amorphous thin film trilayers. In Book of Abstracts of 30th Int. Spring Seminar on Electronics Technology (pp. 140–141). http://hdl.handle.net/20.500.12708/70067 ( reposiTUm)
Hauser, H., Giouroudi, I., Nicolics, J., Rieger, G., Wecker, J., & Daalmans, G. (2007). MI Effect in Amorphous CoFe Thin film Trilayers and Demonstrator Packaging. In Proc. of 30th Int. Spring Seminar on Electronics Technology (pp. 281–286). http://hdl.handle.net/20.500.12708/70064 ( reposiTUm)
Brenner, W., Sümecz, F., Andrijasevic, D., Giouroudi, I., & Malecki, K. (2006). Advanced Methods and Tools for Handling and Assembly in Microtechnology - a European Approach in the Frame of the FP6 Marie Curie Research Training Network ASSEMIC. In 42nd International Conference on Microelectronics, Devices and Materials - Proceedings (pp. 57–68). MIDEM. http://hdl.handle.net/20.500.12708/69524 ( reposiTUm)
Andrijasevic, D., Giouroudi, I., Smetana, W., Brenner, W., & Malecki, K. (2006). Multilayer Adhesive Bonding under Hot Air Stream. In IMAPS International Conference and Exhibition on Device Packaging - Extended Abstracts & Final Program. IMAPS International Conference and Exhibition on Device Packaging - IMAPS 2006, Scottsdale, Arizona, USA, Non-EU. IMAPS. http://hdl.handle.net/20.500.12708/69529 ( reposiTUm)
Giouroudi, I., Kosel, J., Andrijasevic, D., & Brenner, W. (2006). Design of a Microgripping System for Microhandling ans Assembly. In AED 2006 - Advanced Engineering Design (p. 6). http://hdl.handle.net/20.500.12708/69526 ( reposiTUm)
Cvetanovic, A., Cvetanovic, A., Andrijasevic, D., Giouroudi, I., & Brenner, W. (2006). A Novel Protective Cover in Assembling of Micro Components in a SEM Chamber. In Proceeding of the 2006 IEEE Conference on Automation Science and Engineering (p. 5). IEEE. http://hdl.handle.net/20.500.12708/69527 ( reposiTUm)
Giouroudi, I., Kosel, J., Andrijasevic, D., Hötzendorfer, H., Pfützner, H., Brenner, W., & Bleicher, F. (2006). Magnetostrictive Bilayer Sensor for Micro Torque Measurements. In European Magnetic Sensors & Actuators Conference (pp. 153–161). Book of Abstracts EMSA 2006. http://hdl.handle.net/20.500.12708/66158 ( reposiTUm)
Giouroudi, I., Kosel, J., Contreras, J., Pfützner, H., Andrijasevic, D., & Brenner, W. (2006). Evaluation of Micromotors. In Proceedings of the 6th International conference euspen (pp. 159–162). euspen. http://hdl.handle.net/20.500.12708/69455 ( reposiTUm)
Giouroudi, I., Hötzendorfer, H., Andrijasevic, D., Ferros, M., & Brenner, W. (2006). Design of a Microgripping System with Visual and Force Feedback for MEMS applications. In The IET Seminar on MEMS Sensors & Actuators (pp. 245–249). Institution of Engineering and Technology. http://hdl.handle.net/20.500.12708/69456 ( reposiTUm)
Giouroudi, I., Hötzendorfer, H., & Brenner, W. (2006). A Force Feedback System for Micromanipulation with Stereoscopic Imaging. In MNE 2006 - Book of Abstracts (pp. 411–412). http://hdl.handle.net/20.500.12708/69457 ( reposiTUm)
Giouroudi, I., Hauser, H., Musiejovsky, L., & Steurer, J. (2006). Hysteresis Modeling of Giant Magnetoimpedance Thin Films. In Book of Abstracts EMSA 2006 (p. 128). http://hdl.handle.net/20.500.12708/69511 ( reposiTUm)
Brenner, W., Giouroudi, I., & Andrijasevic, D. (2006). Handling and Assembly in Micro Domain. In mna 2006 - Proceedings (pp. 155–156). http://hdl.handle.net/20.500.12708/69518 ( reposiTUm)
Andrijasevic, D., Giouroudi, I., Smetana, W., & Brenner, W. (2006). Low Temperature Non-Viscous Adhesive Bonding in MEMS. In ISSE 2006 - Nano Technologies for Electronics Packaging (pp. 24–25). Verlag Dr. Markus A. Detert. http://hdl.handle.net/20.500.12708/69519 ( reposiTUm)
Andrijasevic, D., Giouroudi, I., Smetana, W., Brenner, W., & Esinenco, D. (2006). Thermal Characterization of the Micro Bonding Process Using a Hot Air Stream. In 25th International Conference on Microelectronics - Proceedings (pp. 267–270). IEEE. http://hdl.handle.net/20.500.12708/69520 ( reposiTUm)
Giouroudi, I., Kosel, J., Pfützner, H., & Brenner, W. (2006). Test Device for Rotating Microsystems. In MNE 2006 - Book of Abstracts (pp. 445–446). http://hdl.handle.net/20.500.12708/69458 ( reposiTUm)
Giouroudi, I., Hauser, H., Nicolics, J., & Musiejovsky, L. (2006). GMI Effect in Laser Micromachined Wire-Sensors. In Magnetic Measurements ’06 - The Book of Abstracts (pp. 95–96). Slovak University of Technology. http://hdl.handle.net/20.500.12708/69459 ( reposiTUm)
Hauser, H., Stangl, G., Janiba, M., & Giouroudi, I. (2006). Measurements and Layout of Sensitive AMR Sensors. In Magnetic Measurements ’06 - The Book of Abstracts (pp. 11–12). Slovak University of Technology. http://hdl.handle.net/20.500.12708/69460 ( reposiTUm)
Cvetanovic, A., Cvetanovic, A., Andrijasevic, D., Giouroudi, I., & Brenner, W. (2006). A novel protective cover for microcomponents. In 4M 2006 - Second international conference on multi-material micro manufacture - Proceedings (pp. 369–372). Elsevier. http://hdl.handle.net/20.500.12708/69453 ( reposiTUm)
Giouroudi, I., Andrijasevic, D., Hötzendorfer, H., Kosel, J., & Brenner, W. (2006). Developemnet of a Microgripping System for Handling of Micro Components. In Proceedings of the 6th International conference euspen (pp. 369–372). euspen. http://hdl.handle.net/20.500.12708/69454 ( reposiTUm)
Hötzendorfer, H., & Giouroudi, I. (2006). Micromanipulation System with Stereoscopic Imaging. In Proceedings of the 12th IASTED International Conference ROBOTICS AND APPLICATIONS (pp. 169–173). http://hdl.handle.net/20.500.12708/69462 ( reposiTUm)
Hötzendorfer, H., Giouroudi, I., Bou, S., & Ferros, M. (2006). Evaluation of Different Control Algorithms for Micromanipulation Systems. In J. Bilbao, A. Olozaga, Y. Ruiz, & C. Cabredo (Eds.), 2006 International Conference on Engineering and Mathematics (pp. 287–294). Publicaciones - Escuela Tecnica Superior de Ingeneria. http://hdl.handle.net/20.500.12708/40663 ( reposiTUm)
Hauser, H., Steurer, J., Mündlein, M., Giouroudi, I., Musiejovsky, L., Zehetner, J., & Nicolics, J. (2006). Laser Welding of GMI-Wire for Magnetic Field Sensors. In Tagungsband Informationstagung Mikroelektronik 06 (pp. 86–92). http://hdl.handle.net/20.500.12708/69512 ( reposiTUm)
Nicolics, J., Musiejovsky, L., Mündlein, M., Zehetner, J., Steurer, J., Giouroudi, I., & Hauser, H. (2006). Laser Welding Process and Packaging for Magnetic Field Sensors. In Proc. of. 29th Int. Spring Seminar on Electronics Technology (pp. 469–474). http://hdl.handle.net/20.500.12708/70070 ( reposiTUm)
Andrijasevic, D., Giouroudi, I., Smetana, W., Boehm, S., & Brenner, W. (2006). Hot Gas Stream Application in Micro-bonding Technique. In Proceedings of SPIE on CD-ROM: Photonics West 2006: MOEMS, MEMS, Micro and Nanofabrication (p. 8). SPIE. https://doi.org/10.1117/12.644688 ( reposiTUm)
Giouroudi, I., Hauser, H., Musiejovsky, L., & Steurer, J. (2005). GMI Sensor integrated in an oscillator system. In Book of Abstracts - 50th Annual Conference on Magnetism and Magnetic Materials (pp. 70–71). http://hdl.handle.net/20.500.12708/68992 ( reposiTUm)
Brenner, W., Sümecz, F., Andrijasevic, D., & Giouroudi, I. (2005). Strategies and Solutions for Handling of Micro Components. In W. Brenner, F. Sümecz, I. Giouroudi, & D. Andrijasevic (Eds.), Micro and nanotechnologies and Multifunctional Materials For Life quality and Industry applications. http://hdl.handle.net/20.500.12708/68956 ( reposiTUm)
Andrijasevic, D., Giouroudi, I., Smetana, W., Homolka, H., Boehm, S., & Brenner, W. (2005). New Approach to Micro-joing by Hot Gas Stream. In MNE2005 - 31st International Conference on Micro- and Nano-Engineering 2005 - Abstracts. MNE2005 - 31st International Conference on Micro- and Nano-Engineering 2005, Wien, Austria. http://hdl.handle.net/20.500.12708/68962 ( reposiTUm)
Giouroudi, I., Hauser, H., Musiejovsky, L., & Steurer, J. (2005). CoFeB/Cu/CoFeB layered film for Giant Magneto-Impedance. In Short Paper Proceedings ISEM 2005 (pp. 72–73). http://hdl.handle.net/20.500.12708/68655 ( reposiTUm)

Beiträge in Büchern

Kokkinis, G., Cardoso, S. F., & Giouroudi, I. (2016). Chapter 7.: Biosensors based on Magnetic Nanoparticles. In Book Series: Advances in Sensors: Reviews - Sensors and Applications in Measuring and Automation Control Systems (pp. 133–145). International Frequency Sensor Association (IFSA) Publishing. http://hdl.handle.net/20.500.12708/29344 ( reposiTUm)
Gooneratne, C., Giouroudi, I., & Kosel, J. (2012). Microdevice with Half-Ring Shaped GMR Sensors for Magnetic Bead Manipulation and Detection. In Advancements in Sensing Technology: New Developments and Practical Applications (pp. 121–138). Springer-Verlag. http://hdl.handle.net/20.500.12708/27729 ( reposiTUm)

Tagungsbände

Giouroudi, I., Petritsch, J. A., & Maity, R. (Eds.). (2025). International Conference on Engineering for Life Sciences : ENROL 2025 : Book of Abstracts. https://doi.org/10.34726/9799 ( reposiTUm)

Präsentationen

Malec, A., Christoph Haiden, Kokkinis, G., & Giouroudi, I. (2025, May 21). Microfluidic Platform combined with a Dark Field Imaging System for Quantification of E. coli Contamination in Water [Poster Presentation]. Biosensors 2025, Lisbon, Portugal. ( reposiTUm)
Giouroudi, I. (2015). Biomedical Applications of Magnetic Nanoparticles. Energy Materials Nanotechnology Fall Meeting (EMN), Istanbul, Turkey. http://hdl.handle.net/20.500.12708/90616 ( reposiTUm)
Giouroudi, I. (2014). Magnetic Microfluidics for Biosensors. 1-Day Workshop “New Materials for a Better Life,” Spain. http://hdl.handle.net/20.500.12708/90484 ( reposiTUm)
Giouroudi, I. (2014). Biomedical applications of magnetic nanoparticles. Conference on Materials and Applications for Sensors and Transducers (IC-MAST 2014), Bilbao, Spain. http://hdl.handle.net/20.500.12708/90483 ( reposiTUm)
Giouroudi, I. (2014). Microfluidic Biosensors using Magnetic Nanoparticles. Stanford Center for Magnetic Nanotechnology, Stanford, United States of America (the). http://hdl.handle.net/20.500.12708/90485 ( reposiTUm)
Giouroudi, I. (2014). Advanced Biosensors and Nanomaterials. Lecture in Department of Physics, University of South Florida, Florida, United States of America (the). http://hdl.handle.net/20.500.12708/90486 ( reposiTUm)
Kokkinis, G., Dangl, A., Keplinger, F., & Giouroudi, I. (2013). Microfluidic biosensing method using the motion of magnetic microparticles. International Conference on Materials and Applications for Sensors and Transducers (IC-MAST) 2013, Prag, Czechia. http://hdl.handle.net/20.500.12708/90494 ( reposiTUm)
Giouroudi, I., Gooneratne, C., & Kokkinis, G. (2013). Controlled trapping and detection of magnetic particles by a magnetic microactuator and a giant magnetoresistance (GMR) sensor. International Conference on Materials and Applications for Sensors and Transducers (IC-MAST) 2013, Prag, Czechia. http://hdl.handle.net/20.500.12708/90274 ( reposiTUm)
Giouroudi, I. (2011). Magnetic Materials: Fundamentals, Fabricationm, Characterization Techniques. Invited Lectures of Magnetic Materials, Sensors, Particles, Prag, Czechia. http://hdl.handle.net/20.500.12708/89660 ( reposiTUm)
Giouroudi, I. (2011). Magnetic Sensors, Actuators and Applications in Intelligent Buildings. Invited Lectures of Magnetic Materials, Sensors, Particles, Prag, Czechia. http://hdl.handle.net/20.500.12708/89661 ( reposiTUm)
Giouroudi, I. (2011). Biosensing using Magnetic Particles. Invited Lectures of Magnetic Materials, Sensors, Particles, Prag, Czechia. http://hdl.handle.net/20.500.12708/89662 ( reposiTUm)
Giouroudi, I. (2011). Magnetism: History, Astrophysics, Fundamentals, Magnetic State of Matter. Invited Lectures of Magnetic Materials, Sensors, Particles, Prag, Czechia. http://hdl.handle.net/20.500.12708/89663 ( reposiTUm)
Giouroudi, I. (2011). Magnetic based sensors for biomedical applications. VAC-Kolloquium, Hanau, Germany. http://hdl.handle.net/20.500.12708/89403 ( reposiTUm)
Giouroudi, I. (2011). Biomedical Sensing Applications of Magnetic Materials. Seminar at the University of Tasmania - Faculty of Science, Engineering & Technology - School of Chemistry, Hobart, Australia. http://hdl.handle.net/20.500.12708/89543 ( reposiTUm)
Giouroudi, I., Van den Driesche, S., & Kosel, J. (2010). Biosensing Utilizing the Motion of Magnetic Microparticles in a Microfluidic System. Eurosensors XXIV, Linz, Austria, Austria. http://hdl.handle.net/20.500.12708/89320 ( reposiTUm)
Hauser, H., Giouroudi, I., Musiejovsky, L., Stangl, G., & Steurer, J. (2005). Magnetoimpedance Effect in Thin Films and Applications in Passive and Wireless Sensors. Symposium “Magnetoresistive Sensoren VI: Grundlagen - Herstellung - Anwendung,” Wetzlar, Germany, EU. http://hdl.handle.net/20.500.12708/88466 ( reposiTUm)
Hauser, H., Giouroudi, I., Musiejovsky, L., Stangl, G., & Steurer, J. (2005). Magneto-Impedanz Strukturen in Dünnschichttechnik für passive und Drahtlose Sensoren. Dornbirner Mikrotechniktage, Dornbirn, Austria. http://hdl.handle.net/20.500.12708/88467 ( reposiTUm)

Berichte

Hauser, H., Giouroudi, I., Musiejovsky, L., & Steurer, J. (2005). NonContact Magnetic Field Sensor. http://hdl.handle.net/20.500.12708/31181 ( reposiTUm)
Hauser, H., & Giouroudi, I. (2003). Magneto-Impedance Thin Film Demonstrator. http://hdl.handle.net/20.500.12708/31185 ( reposiTUm)

Hochschulschriften

Giouroudi, I. (2006). Magnetoimpedance-Microstructures [Dissertation, Technische Universität Wien]. reposiTUm. http://hdl.handle.net/20.500.12708/184393 ( reposiTUm)