<div class="csl-bib-body">
<div class="csl-entry">Krampe, J. (2011). Full scale evaluation of diffuser ageing with clean water oxygen transfer tests. <i>Water Science and Technology</i>, <i>64</i>(3), 700–707. https://doi.org/10.2166/wst.2011.694</div>
</div>
-
dc.identifier.issn
0273-1223
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/114
-
dc.description
The final publication is available via <a href="https://doi.org/10.2166/wst.2011.694" target="_blank">https://doi.org/10.2166/wst.2011.694</a>.
-
dc.description.abstract
Aeration is a crucial part of the biological wastewater treatment in activated sludge systems and the main energy user of WWTPs. Approximately 50 to 60% of the total energy consumption of a WWTP can be attributed to the aeration system. The performance of the aeration system, and in the case of fine bubble diffused aeration the diffuser performance, has a significant impact on the overall plant efficiency. This paper seeks to isolate the changes of the diffuser performance over time by eliminating all other influencing parameters like sludge retention time, surfactants and reactor layout. To achieve this, different diffusers have been installed and tested in parallel treatment trains in two WWTPs. The diffusers have been performance tested in clean water tests under new conditions and after one year of operation. A set of material property tests describing the diffuser membrane quality was also performed. The results showed a significant drop in the performance of the EPDM diffuser in the first year which resulted in similar oxygen transfer efficiency around 16 g/m3/m for all tested systems. Even though the tested silicone diffusers did not show a drop in performance they had a low efficiency in the initial tests. The material properties indicate that the EPDM performance loss is partly due to the washout of additives.
en
dc.language
English
-
dc.language.iso
en
-
dc.publisher
IWA PUBLISHING
-
dc.relation.ispartof
Water Science and Technology
-
dc.rights.uri
http://rightsstatements.org/vocab/InC/1.0/
-
dc.subject
aeration systems
en
dc.subject
diffuser ageing
en
dc.subject
membrane diffuser
en
dc.subject
oxygen transfer
en
dc.title
Full scale evaluation of diffuser ageing with clean water oxygen transfer tests
en
dc.type
Article
en
dc.type
Artikel
de
dc.rights.license
In Copyright
en
dc.rights.license
Urheberrechtsschutz
de
dc.description.startpage
700
-
dc.description.endpage
707
-
dc.rights.holder
IWA Publishing 2011
-
dc.type.category
Original Research Article
-
tuw.container.volume
64
-
tuw.container.issue
3
-
tuw.journal.peerreviewed
true
-
tuw.peerreviewed
true
-
tuw.version
am
-
dcterms.isPartOf.title
Water Science and Technology
-
tuw.publication.orgunit
E226-01 - Forschungsbereich Wassergütewirtschaft
-
tuw.publisher.doi
10.2166/wst.2011.694
-
dc.identifier.eissn
1996-9732
-
dc.identifier.libraryid
AC15321012
-
dc.description.numberOfPages
8
-
dc.identifier.urn
urn:nbn:at:at-ubtuw:3-4965
-
tuw.author.orcid
0000-0002-7757-4163
-
dc.rights.identifier
In Copyright
en
dc.rights.identifier
Urheberrechtsschutz
de
item.fulltext
with Fulltext
-
item.grantfulltext
open
-
item.openairecristype
http://purl.org/coar/resource_type/c_2df8fbb1
-
item.cerifentitytype
Publications
-
item.languageiso639-1
en
-
item.openairetype
research article
-
item.openaccessfulltext
Open Access
-
item.mimetype
application/pdf
-
crisitem.author.dept
E226-01 - Forschungsbereich Wassergütewirtschaft
-
crisitem.author.orcid
0000-0002-7757-4163
-
crisitem.author.parentorg
E226 - Institut für Wassergüte und Ressourcenmanagement