<div class="csl-bib-body">
<div class="csl-entry">Zoratto, S., Weiss, V., Friedbacher, G., Buengener, C., Pletzenauer, R., Foettinger-Vacha, A., Graninger, M., & Allmaier, G. (2021). Adeno-associated Virus Virus-like Particle Characterization via Orthogonal Methods: Nanoelectrospray Differential Mobility Analysis, Asymmetric Flow Field-Flow Fractionation, and Atomic Force Microscopy. <i>ACS Omega</i>, <i>6</i>(25), 16428–16437. https://doi.org/10.1021/acsomega.1c01443</div>
</div>
-
dc.identifier.issn
2470-1343
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/138765
-
dc.description.abstract
Adeno-associated virus (AAV)-based virus-like particles (VLPs) are thriving vectors of choice in the biopharmaceutical field of gene therapy. Here, a method to investigate purified AAV serotype 8 (AAV8) batches via a nanoelectrospray gas-phase mobility molecular analyzer (nES GEMMA), also known as an nES differential mobility analyzer, is presented. Indeed, due to AAV's double-digit nanometer scale, nES GEMMA is an excellently suited technique to determine the surface-dry particle size termed electrophoretic mobility diameter of such VLPs in their native state at atmospheric pressure and with particle-number-based detection. Moreover, asymmetric flow field-flow fractionation (AF4, also known as AFFFF) and atomic force microscopy (AFM) techniques were employed as orthogonal techniques for VLP characterization. In addition, AF4 was implemented to size-separate as well as to enrich and collect fractions of AAV8 VLPs after inducing analyte aggregation in the liquid phase. Bionanoparticle aggregation was achieved by a combination of heat and shear stress. These fractions were later analyzed with nES GEMMA (in the gas phase) and AFM (on a solid surface). Both techniques confirm the presence of dimers, trimers, and putative VLP oligomers. Last, AFM reveals even larger AAV8 VLP aggregates, which were not detectable by nES GEMMA because their heterogeneity combined with low abundance was below the limit of detection of the instrument. Hence, the combination of the employed orthogonal sizing methods with the separation technique AF4 allow a comprehensive characterization of AAV8 VLPs applied as vectors.
en
dc.language.iso
en
-
dc.relation.ispartof
ACS Omega
-
dc.subject
General Chemistry
en
dc.subject
General Chemical Engineering
en
dc.title
Adeno-associated Virus Virus-like Particle Characterization via Orthogonal Methods: Nanoelectrospray Differential Mobility Analysis, Asymmetric Flow Field-Flow Fractionation, and Atomic Force Microscopy
en
dc.type
Artikel
de
dc.type
Article
en
dc.description.startpage
16428
-
dc.description.endpage
16437
-
dc.type.category
Original Research Article
-
tuw.container.volume
6
-
tuw.container.issue
25
-
tuw.journal.peerreviewed
true
-
tuw.peerreviewed
true
-
tuw.researchTopic.id
M6
-
tuw.researchTopic.name
Biological and Bioactive Materials
-
tuw.researchTopic.value
100
-
dcterms.isPartOf.title
ACS Omega
-
tuw.publication.orgunit
E164-01-2 - Forschungsgruppe Oberflächen-, Spurenanalytik und Chemometrie
-
tuw.publication.orgunit
E164-01-1 - Forschungsgruppe Massenspektrometrische Bio- und Polymeranalytik
-
tuw.publisher.doi
10.1021/acsomega.1c01443
-
dc.identifier.eissn
2470-1343
-
dc.description.numberOfPages
10
-
tuw.author.orcid
0000-0002-1491-3404
-
tuw.author.orcid
0000-0002-0056-6819
-
tuw.author.orcid
0000-0002-1438-9462
-
wb.sci
true
-
wb.sciencebranch
Chemie
-
wb.sciencebranch
Biologie
-
wb.sciencebranch.oefos
1040
-
wb.sciencebranch.oefos
1060
-
wb.facultyfocus
Bioscience Technology
de
wb.facultyfocus
Bioscience Technology
en
wb.facultyfocus.faculty
E150
-
item.openairetype
research article
-
item.fulltext
no Fulltext
-
item.openairecristype
http://purl.org/coar/resource_type/c_2df8fbb1
-
item.grantfulltext
restricted
-
item.cerifentitytype
Publications
-
item.languageiso639-1
en
-
crisitem.author.dept
E164-01-1 - Forschungsgruppe Massenspektrometrische Bio- und Polymeranalytik
-
crisitem.author.dept
E164-01-1 - Forschungsgruppe Massenspektrometrische Bio- und Polymeranalytik
-
crisitem.author.dept
E164-01-2 - Forschungsgruppe Oberflächen-, Spurenanalytik und Chemometrie
-
crisitem.author.dept
E164-01-1 - Forschungsgruppe Massenspektrometrische Bio- und Polymeranalytik
-
crisitem.author.orcid
0000-0002-1491-3404
-
crisitem.author.orcid
0000-0002-0056-6819
-
crisitem.author.orcid
0000-0002-1438-9462
-
crisitem.author.parentorg
E164-01 - Forschungsbereich Imaging und Instrumentelle Analytische Chemie
-
crisitem.author.parentorg
E164-01 - Forschungsbereich Imaging und Instrumentelle Analytische Chemie
-
crisitem.author.parentorg
E164-01 - Forschungsbereich Imaging und Instrumentelle Analytische Chemie
-
crisitem.author.parentorg
E164-01 - Forschungsbereich Imaging und Instrumentelle Analytische Chemie