<div class="csl-entry">Coutts, L. V., Jenkins, T., Li, T., Dunlop, D. G., Oreffo, R. O. C., Cooper, C., Harvey, N. C., & Thurner, P. (2015). Variability in Reference Point Microindentation and Recommendations for Testing Cortical Bone: Location, Thickness,and Orientation Heterogeneity. <i>Journal of the Mechanical Behavior of Biomedical Materials</i>, <i>46</i>, 292–304. https://doi.org/10.1016/j.jmbbm.2015.02.004</div>
</div>
-
dc.identifier.issn
1751-6161
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/150862
-
dc.description.abstract
Reference Point Indentation (RPI) has been proposed as a new clinical tool to aid the diagnosis of Osteoporosis. This study has examined the performance of the tool within entire femurs to improve the understanding of the mechanical properties of bone and also to guide future RPI testing to optimize repeatability of results obtained using the technique. Human, bovine, porcine and rat femurs were indented along three longitudinal axes: anterior and posterior: medial and lateral as well as around the circumference of the femoral head and neck. Cortical and subchondral bone thickness was measured using CT and radiography. The study shows that in some samples, bone is too thin to support the high loads applied with the technique and in these cases, RPI values are highly influenced by thickness. The technique will be useful in the mid-shaft region where cortical thickness is greatest, providing previously established guidelines are followed to optimize measurement repeatability, including performing multiple measurements per sample and investigating multiple samples. The study has also provided evidence that RPI values vary significantly with test site, hence mechanical properties should not be inferred from RPI findings alone away from the test site, even within the same bone. In conclusion, RPI appears to be a useful tool for scientific investigation; however further work is required to examine the feasibility of using RPI for assessing differences between healthy and diseased bone in a clinical setting.
en
dc.language.iso
en
-
dc.publisher
Elsevier
-
dc.relation.ispartof
Journal of the Mechanical Behavior of Biomedical Materials
-
dc.subject
Mechanics of Materials
-
dc.subject
Biomedical Engineering
-
dc.subject
Biomaterials
-
dc.title
Variability in Reference Point Microindentation and Recommendations for Testing Cortical Bone: Location, Thickness,and Orientation Heterogeneity
en
dc.type
Artikel
de
dc.type
Article
en
dc.description.startpage
292
-
dc.description.endpage
304
-
dc.type.category
Original Research Article
-
tuw.container.volume
46
-
tuw.journal.peerreviewed
true
-
tuw.peerreviewed
true
-
tuw.researchTopic.id
M6
-
tuw.researchTopic.name
Biological and Bioactive Materials
-
tuw.researchTopic.value
100
-
dcterms.isPartOf.title
Journal of the Mechanical Behavior of Biomedical Materials
-
tuw.publication.orgunit
E317-02 - Forschungsbereich Biomechanik
-
tuw.publisher.doi
10.1016/j.jmbbm.2015.02.004
-
dc.identifier.eissn
1878-0180
-
dc.description.numberOfPages
13
-
tuw.author.orcid
0000-0001-7588-9041
-
wb.sci
true
-
wb.sciencebranch
Medizintechnik
-
wb.sciencebranch.oefos
2060
-
wb.facultyfocus
Außerhalb der primären Forschungsgebiete der Fakultät
de
wb.facultyfocus
Outside the Faculty's primary research activities
en
item.languageiso639-1
en
-
item.openairetype
research article
-
item.grantfulltext
none
-
item.fulltext
no Fulltext
-
item.cerifentitytype
Publications
-
item.openairecristype
http://purl.org/coar/resource_type/c_2df8fbb1
-
crisitem.author.dept
E317 - Institut für Leichtbau und Struktur-Biomechanik
-
crisitem.author.orcid
0000-0001-7588-9041
-
crisitem.author.parentorg
E300 - Fakultät für Maschinenwesen und Betriebswissenschaften