<div class="csl-bib-body">
<div class="csl-entry">Weber, T., Wassertheurer, S., O’Rourke, M. F., Haiden, A., Zweiker, R., Rammer, M., Hametner, B., & Eber, B. (2013). Pulsatile Hemodynamics in Patients With Exertional Dyspnea: Potentially of Value in the Diagnostic Evaluation of Suspected Heart Failure With Preserved Ejection Fraction. <i>Journal of the American College of Cardiology</i>, <i>61</i>(18), 1874–1883. https://doi.org/10.1016/j.jacc.2013.02.013</div>
</div>
-
dc.identifier.issn
0735-1097
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/155614
-
dc.description.abstract
Objectives This study sought to test whether measures of pulsatile arterial function are useful for diagnosing heart failure with preserved ejection fraction (HFPEF), in comparison with and in addition to tissue Doppler echocardiography (TDE).
Background Increased arterial stiffness and wave reflections are present in most patients with HFPEF.
Methods Patients with dyspnea as a major symptom were categorized as having HFPEF or no HFPEF, based on invasively derived filling pressures and natriuretic peptide levels. Pulse wave velocity (PWV) was measured invasively (aortic PWV). Aortic pulse pressure (aoPP) and its components (incident pressure wave height, forward wave amplitude; augmented pressure; backward wave amplitude [Pb]) were quantified noninvasively.
Results Seventy-one patients were classified as HFPEF and 65 as no HFPEF (223 patients had intermediate results). Patients with HFPEF were older, more often had hypertension and diabetes, and had larger left atria and higher left ventricular mass. Brachial pulse pressure (bPP), aoPP, and all measures of arterial stiffness and wave reflections were higher in HFPEF patients. Receiver-operating curve analysis-derived area under the curve (AUC) values for separating HFPEF from no HFPEF were 0.823 for E/E′ at the medial annulus, the best TDE parameter; 0.816 for bPP; and 0.867, 0.851, and 0.825 for aortic PWV, aoPP, and Pb, respectively. Adding measures of pulsatile function to TDE resulted in an increase in AUC to 0.875 (bPP; p = 0.03) and 0.901 (aoPP; p = 0.005). In comparison with a TDE-based algorithm, net reclassification improvement was 32.9% (p < 0.0001).
Conclusions Measures of pulsatile arterial hemodynamics may complement TDE for the diagnosis of HFPEF. (Pulsatile and Steady State Hemodynamics in Diastolic Heart Failure; NCT00720525)
en
dc.language.iso
en
-
dc.publisher
ELSEVIER SCIENCE INC
-
dc.relation.ispartof
Journal of the American College of Cardiology
-
dc.subject
arterial stiffness
-
dc.subject
Cardiology and Cardiovascular Medicine
-
dc.subject
arterial wave reflections
-
dc.subject
exertional dyspnea
-
dc.subject
heart failure with preserved ejection fraction
-
dc.subject
pulsatile hemodynamics.
-
dc.title
Pulsatile Hemodynamics in Patients With Exertional Dyspnea: Potentially of Value in the Diagnostic Evaluation of Suspected Heart Failure With Preserved Ejection Fraction
en
dc.type
Artikel
de
dc.type
Article
en
dc.description.startpage
1874
-
dc.description.endpage
1883
-
dc.type.category
Original Research Article
-
tuw.container.volume
61
-
tuw.container.issue
18
-
tuw.journal.peerreviewed
true
-
tuw.peerreviewed
true
-
tuw.researchTopic.id
X1
-
tuw.researchTopic.id
C6
-
tuw.researchTopic.name
außerhalb der gesamtuniversitären Forschungsschwerpunkte
-
tuw.researchTopic.name
Modelling and Simulation
-
tuw.researchTopic.value
20
-
tuw.researchTopic.value
80
-
dcterms.isPartOf.title
Journal of the American College of Cardiology
-
tuw.publication.orgunit
E101-03 - Forschungsbereich Scientific Computing and Modelling
-
tuw.publisher.doi
10.1016/j.jacc.2013.02.013
-
dc.identifier.eissn
1558-3597
-
dc.description.numberOfPages
10
-
wb.sci
true
-
wb.sciencebranch
Mathematik, Informatik
-
wb.sciencebranch
Sonstige und interdisziplinäre Humanmedizin
-
wb.sciencebranch.oefos
11
-
wb.sciencebranch.oefos
39
-
wb.facultyfocus
Analysis und Scientific Computing
de
wb.facultyfocus
Analysis and Scientific Computing
en
wb.facultyfocus.faculty
E100
-
item.openairecristype
http://purl.org/coar/resource_type/c_18cf
-
item.openairecristype
http://purl.org/coar/resource_type/c_18cf
-
item.grantfulltext
none
-
item.fulltext
no Fulltext
-
item.openairetype
Artikel
-
item.openairetype
Article
-
item.cerifentitytype
Publications
-
item.cerifentitytype
Publications
-
item.languageiso639-1
en
-
crisitem.author.dept
E363 - Institut für Biomedizinische Elektronik
-
crisitem.author.dept
E363 - Institut für Biomedizinische Elektronik
-
crisitem.author.parentorg
E350 - Fakultät für Elektrotechnik und Informationstechnik
-
crisitem.author.parentorg
E350 - Fakultät für Elektrotechnik und Informationstechnik