<div class="csl-bib-body">
<div class="csl-entry">Pölzl, T. (2013). <i>Adaption und Dimensionierung des Multifunktionellen Dynamometers (MDS) für die Anwendung in der Schwerelosigkeit gemäß des Anforderungskataloges für die Parabelflüge</i> [Diploma Thesis, Technische Universität Wien]. reposiTUm. http://hdl.handle.net/20.500.12708/159977</div>
</div>
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/159977
-
dc.description
Abweichender Titel laut Übersetzung der Verfasserin/des Verfassers
-
dc.description
Zsfassung in engl. Sprache
-
dc.description.abstract
Ziel dieser Diplomarbeit ist die Adaption und Dimensionierung der Befestigung eines Trainingsgerätes für Schwerelosigkeit in einem Airbus A300 Zero-G für die Anwendung während Parabelflügen. Das zu montierende Trainingsgerät MDS („Multifunctional Dynamometer for Application in Space“) dient zum Kraft- und Ausdauertraining in Schwerelosigkeit. Ein Servo-Syncron-Motor, erzeugt die Zug-Kraft, welche mit zwei Seilzügen auf eine frei bewegliche Hantelstange übertragen wird. Durch intensives Muskeltraining soll somit auf Weltallmissionen dem Muskel- und Knochenschwund entgegengewirkt werden. Im Zuge einer Parabelflugkampagne soll die Gravitationsphysiologie und Muskelaktivierung während des Trainings mit dem MDS unter Mikrogravitationsbedingungen untersucht werden. Zu diesem Zweck wurde die bestehende Konstruktion des MDS hinsichtlich des „Anforderungskatalog“ der Französischen Parabelflugunternehmens NOVESPACE untersucht. Die Ergebnisse der relevanten Strukturen wurden laut „Anforderungskatalog“ berechnet und dargestellt. Da diverse Berechnungs-Modelle des „Anforderungskatalogs“ keine realitätsnahen Ergebnisse liefern können, wurden bei kritischen Bauteilen zusätzliche Berechnungen durchgeführt. Abschließend erfolgten die Erstellung von Fertigungszeichnungen mit einem 3D-CAD-Software und eine Abschätzung des Materialaufwands.
de
dc.description.abstract
The main goal of this thesis is the adaption and design of the fixations of a training tool to an Airbus A-300 Zero-G for application during parabolic flights. The MDS („Multifunctional Dynamometer for Application in Space“) is used for physical weight- and endurance-training at zero gravity conditions. A servo-synchronous motor, generates the force which is transferred to a rod by two wire-rope-mechanisms. By this type of muscle training the MDS helps to combat the issues of muscle and bone loss during long space missions. The gravitational physiology and muscle activation during a MDS Training at microgravity-conditions shall be examined during a parabolic flight campaign. For this purpose the existing MDS construction was examined relating to the “Rules and Guidelines” (R & G) of the French parabolicflightcompany NOVESPACE. The results of the relevant structures were calculated and presented according to the “Rules and Guidelines”. As some calculation models of the “Rules and Guidelines” are not able to deliver realistic results, additional calculations were made for critical parts. Finally a cost-estimation was made after the technical drawings were completed by using a 3D-CAD-software.
en
dc.language
Deutsch
-
dc.language.iso
de
-
dc.subject
Parabelfug
de
dc.subject
Schwerelosigkeit
de
dc.subject
Muskeltraining
de
dc.subject
Parabelflüge
de
dc.subject
Dynamometer
de
dc.subject
parabolic flight
en
dc.subject
zero gravity
en
dc.subject
muscle training
en
dc.subject
parabolic flights
en
dc.subject
dynamometer
en
dc.title
Adaption und Dimensionierung des Multifunktionellen Dynamometers (MDS) für die Anwendung in der Schwerelosigkeit gemäß des Anforderungskataloges für die Parabelflüge
de
dc.title.alternative
Adaptation and dimensioning of the Multifunctional Dynamometer (MDS) for application at zero gravity conditions according to the guidelines for parabolic flights
en
dc.type
Thesis
en
dc.type
Hochschulschrift
de
dc.contributor.affiliation
TU Wien, Österreich
-
tuw.thesisinformation
Technische Universität Wien
-
tuw.publication.orgunit
E307 - Institut für Konstruktionswissenschaften und technische Logistik