<div class="csl-bib-body">
<div class="csl-entry">Kahl, S., Kofler, T., Pillei, M., & Kraxner, M. (2020). Empirical design parameter study of a bidirectional flow cyclone. In C. Jordan (Ed.), <i>Proceedings of the 16th Minisymposium Verfahrenstechnik and 7th Partikelforum (TU Wien, Sept. 21/22, 2020)</i> (pp. DiV5-(01) page 1-DiV5-(01) page 5). chemical-engineering.at. https://doi.org/10.34726/607</div>
</div>
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/16664
-
dc.identifier.uri
https://doi.org/10.34726/607
-
dc.description.abstract
This paper investigates a cyclonic separator called "Double vortex finder cyclone" (DVFC), a bidirectional flow cyclone, which is distinguished by two coaxially aligned clean gas outlets (vortex finder), resulting therefore in a particularly low pressure drop. Due to lacking experimental data regarding the ideal dimensions and operating conditions, dedusting experiments according to DIN ISO 5011:2014 were conducted. The influence of the vortex finder diameter, of the inlet inflow velocity and of a partially blocked clean gas outlet on the separation efficiency, pressure drop and fractional efficiency were investigated. The specific pressure drop coefficients were determined for each vortex finder diameter. The findings indicate an increasing separation efficiency, pressure drop and fractional efficiency for a higher inlet inflow velocity and a smaller vortex finder diameter. A partially clogged clean gas outlet results in a pressure drop increase but exerts no significant influence on the separation efficiency nor the cut size diameter. Based upon the acquired data, the DVFC has proven to be a promising separator, most notably due to the low pressure drop, with the potential to be considered in some applications as a successor of the established reverse flow cyclone and uniflow cyclone models.
en
dc.language.iso
en
-
dc.rights.uri
http://creativecommons.org/licenses/by/4.0/
-
dc.subject
bidirectional flow cyclone
en
dc.subject
twin flow cyclone
en
dc.subject
multi-phase flow separation
en
dc.subject
geometric design parameter study
en
dc.title
Empirical design parameter study of a bidirectional flow cyclone
en
dc.type
Inproceedings
en
dc.type
Konferenzbeitrag
de
dc.rights.license
Creative Commons Namensnennung 4.0 International
de
dc.rights.license
Creative Commons Attribution 4.0 International
en
dc.identifier.doi
10.34726/607
-
dc.contributor.affiliation
Management Center Innsbruck, Austria
-
dc.contributor.affiliation
Management Center Innsbruck, Austria
-
dc.contributor.affiliation
Management Center Innsbruck, Austria
-
dc.contributor.affiliation
Management Center Innsbruck, Austria
-
dc.relation.isbn
978-3-903337-01-5
-
dc.relation.doi
10.34726/541
-
dc.description.startpage
DiV5-(01) page 1
-
dc.description.endpage
DiV5-(01) page 5
-
dcterms.dateSubmitted
2020-02-29
-
dc.type.category
Full-Paper Contribution
-
tuw.booktitle
Proceedings of the 16th Minisymposium Verfahrenstechnik and 7th Partikelforum (TU Wien, Sept. 21/22, 2020)