dc.description.abstract
Four dimensional microscope-integrated optical coherence tomography (4D-miOCT) has been proposed as an alternative to conventional white light microscopy in ophthalmic surgery. However, the specific method suitable for intraoperative visualization of this large amount of data is still a subject of ongoing research. This thesis investigates the use of an autostereoscopic tablet, while comparing it to already available means of visualization. Using a custom multiVNC based viewer on the client-side, we stream the 4D-miOCT renderings to an autostereoscopic tablet trying to achieve low latency. To compare the quality of visualization of the tablet and TV with that of a state-of-the-art surgical light microscope, we utilized the fastest 4D-miOCT engine and a modern digital ophthalmic surgical microscope. We conducted a user study with 35 participants (14 physicians and 21 laypersons). The user survey included subjective feedback and a quantitative performance assessment, as well as several quantitative measures, such as time to task completion. We were able to stream 4D-miOCT video live to an autostereoscopic light-field tablet, measuring a latency of 151 ms from server to client and a volume rate of 10 volumes-per-second, displaying the 4D-miOCT rendering on a TV. The light microscope and the TV performed best in terms of both performance rating and feedback on the visualizations. The tablet showed shortcomings in terms of resolution, 3D effect and latency, compared to the other visualizations. Subjective feedback suggests that the tablet has great potential to replace the TV. However, for this application to become clinically feasible, issues such as latency, resolution, and the quality of the 3D effect need to be addressed. The feedback collected in the user study, will further enable the optimization of 4D-miOCT streaming and visualization for surgeons during ophthalmic procedures, progressing towards a better integration into the surgical workflow.
en
dc.language
English
-
dc.language.iso
en
-
dc.rights.uri
http://rightsstatements.org/vocab/InC/1.0/
-
dc.subject
Stereoskopie
de
dc.subject
Intraoperativ
de
dc.subject
Visualisierung
de
dc.subject
4D-miOCT
de
dc.subject
Ophthalmologie
de
dc.subject
Benutzerstudie
de
dc.subject
Streaming
de
dc.subject
Stereoscopy
en
dc.subject
Intraoperative
en
dc.subject
Visualization
en
dc.subject
4D-miOCT
en
dc.subject
Ophthalmology
en
dc.subject
User-Study
en
dc.subject
Streaming
en
dc.title
Stereoscopic visualiation of real-time intraoperative 4D-miOCT in opthalmology
en
dc.title.alternative
Stereoskopische Visualisierung intraoperativem 4D-miOCT in der Opthalmologie
de
dc.type
Thesis
en
dc.type
Hochschulschrift
de
dc.rights.license
In Copyright
en
dc.rights.license
Urheberrechtsschutz
de
dc.identifier.doi
10.34726/hss.2023.103220
-
dc.contributor.affiliation
TU Wien, Österreich
-
dc.rights.holder
Florian Kapeller
-
dc.publisher.place
Wien
-
tuw.version
vor
-
tuw.thesisinformation
Technische Universität Wien
-
tuw.publication.orgunit
E193 - Institut für Visual Computing and Human-Centered Technology
-
dc.type.qualificationlevel
Diploma
-
dc.identifier.libraryid
AC16837659
-
dc.description.numberOfPages
185
-
dc.thesistype
Diplomarbeit
de
dc.thesistype
Diploma Thesis
en
dc.rights.identifier
In Copyright
en
dc.rights.identifier
Urheberrechtsschutz
de
tuw.advisor.staffStatus
staff
-
tuw.advisor.orcid
0000-0003-4195-1593
-
item.openaccessfulltext
Open Access
-
item.openairecristype
http://purl.org/coar/resource_type/c_bdcc
-
item.grantfulltext
open
-
item.mimetype
application/pdf
-
item.languageiso639-1
en
-
item.openairetype
master thesis
-
item.fulltext
with Fulltext
-
item.cerifentitytype
Publications
-
crisitem.author.dept
E325 - Institut für Mechanik und Mechatronik
-
crisitem.author.parentorg
E300 - Fakultät für Maschinenwesen und Betriebswissenschaften