<div class="csl-entry">Ulrich-Pur, F., Bergauer, T., Hirtl, A., Irmler, C., Kaser, S., Pitters, F. M., & Rit, S. (2023). Novel ion imaging concept based on time-of-flight measurements with low gain avalanche detectors. <i>Journal of Instrumentation</i>, <i>18</i>(2), Article C02062. https://doi.org/10.1088/1748-0221/18/02/C02062</div>
</div>
-
dc.identifier.issn
1748-0221
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/191247
-
dc.description.abstract
Treatment planning in ion beam therapy requires accurate knowledge of the relative stopping power (RSP) distribution within the patient. Currently, RSP maps are obtained via conventional x-ray computed tomography (CT) by converting the measured attenuation coefficients of photons into RSP values for ions. Alternatively, to avoid conversion errors that are inherent to this method, ion computed tomography (iCT) can be used since it allows determining the RSP directly. In typical iCT systems, which usually consist of a tracking system and a separate residual energy detector, the RSP is obtained by measuring the particle trajectory and the corresponding water equivalent path length (WEPL) of single ions travelling through the patient. In this work, we explore a novel iCT approach which does not require a residual energy detector. Instead, the WEPL is estimated indirectly by determining the change in time of flight (TOF) due to the energy loss along the ion’s path. For this purpose, we have created a Geant4 model of a TOF-iCT system based on low gain avalanche detectors (LGADs), which are fast 4D-tracking detectors that can measure the time of arrival and position of individual particles with high spatial and time precision. To assess the performance of this TOF-iCT concept, we determined the RSP resolution and accuracy for different system settings using the Catphan® CTP404 sensitometry phantom. Within the set of investigated system parameters, the lower limit of the RSP accuracy was found at 0.91%, demonstrating the proof-of-principle of this novel TOF-iCT concept. The main advantage of using this approach is that it could potentially facilitate clinical integration due to its compact design, which, however, requires experimental verification and an improvement of the current WEPL calibration procedure.
en
dc.language.iso
en
-
dc.publisher
IOP PUBLISHING LTD
-
dc.relation.ispartof
Journal of Instrumentation
-
dc.subject
Accelerator applications
en
dc.subject
Image reconstruction in medical imaging
en
dc.subject
Instrumentation for hadron therapy
en
dc.title
Novel ion imaging concept based on time-of-flight measurements with low gain avalanche detectors