<div class="csl-bib-body">
<div class="csl-entry">Nia, A., Jeremic, N., Popp, D., Schmoelz, L., Patsch, J., Döring, K., Weber, M., Synek, A., Pahr, D. H., & Aldrian, S. (2023). Feasibility of aluminum phantom radiography for osteoporosis detection in postmenopausal women with a fragility fracture of the distal radius compared to DXA and HR-pQCT. <i>Journal of Orthopaedic Research</i>, <i>41</i>(8), 1774–1780. https://doi.org/10.1002/jor.25523</div>
</div>
-
dc.identifier.issn
0736-0266
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/191738
-
dc.description.abstract
Recently, promising results have been reported for detection of osteoporosis with use of an aluminum phantom. Therefore, the aim of this study was to evaluate the feasibility of radiography-based bone mineral density (BMD) measurement using a graded aluminum phantom. This study included 27 postmenopausal women with a distal radius fracture. Aluminum phantom radiography of the healthy radius was conducted as well as high-resolution peripheral quantitative computed tomography (HR-pQCT) measurement of the ultradistal radius and dual energy X-ray absorptiometry (DXA) of the radius, spine, and hip. A strong correlation was observed between aluminum phantom radiography-based mean gray value (mGV) and DXA-derived BMD, especially for the ultradistal radius (ρ = 0.75; p < 0.001). A moderate correlation for the femoral neck (ρ = 0.61 and p < 0.001) between modalities was found. Radius mGV and HR-pQCT-derived BMD only showed a moderate correlation (ρ = 0.48; p < 0.09). Aluminum phantom radiography might serve as a cost efficient, highly available, low-radiation dose screening, and diagnostic method for osteoporosis additively to DXA measurements. Especially, an application in areas with constrained DXA availability and such as preoperative trauma settings would be beneficial. However, further investigation and assessment of specificity and sensitivity is needed.
en
dc.language.iso
en
-
dc.publisher
Wiley
-
dc.relation.ispartof
Journal of Orthopaedic Research
-
dc.rights.uri
http://creativecommons.org/licenses/by-nc-nd/4.0/
-
dc.subject
Female
en
dc.subject
Humans
en
dc.subject
Absorptiometry, Photon
en
dc.subject
Radius
en
dc.subject
Aluminum
en
dc.subject
Postmenopause
en
dc.subject
Feasibility Studies
en
dc.subject
Bone Density
en
dc.subject
DXA
en
dc.subject
HR-pQCT
en
dc.subject
aluminum phantom
en
dc.subject
bone mineral density
en
dc.subject
osteoporosis
en
dc.subject
Osteoporosis
en
dc.subject
Fractures, Bone
en
dc.subject
Osteoporosis, Postmenopausal
en
dc.title
Feasibility of aluminum phantom radiography for osteoporosis detection in postmenopausal women with a fragility fracture of the distal radius compared to DXA and HR-pQCT
en
dc.type
Article
en
dc.type
Artikel
de
dc.rights.license
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
en
dc.rights.license
Creative Commons Namensnennung - Nicht kommerziell - Keine Bearbeitungen 4.0 International