<div class="csl-bib-body">
<div class="csl-entry">Jarić, S., Schobesberger, S., Ertl, P., Knežević, N. Ž., & Bobrinetskiy, I. (2024). Electrochemical Detection of MMP-2 Using Graphene-Based Aptasensor. <i>Proceedings</i>, <i>97</i>(1), Article 57. https://doi.org/10.3390/proceedings2024097057</div>
</div>
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/205624
-
dc.description.abstract
A graphene-based electrochemical biosensor was developed for the detection of matrix metalloproteinase 2 (MMP-2) endopeptidase, whose expression can be significantly related to the occurrence, metastasis, and prognosis of cancer. A specific anti-MMP-2 aptamer was successfully immobilized on the surface of electrochemically reduced graphene oxide via a pyrene-based linker, enabling the specific capture of MMP-2. The sensor was able to detect 1 ng mL⁻¹, with an overall detection time of less than 20 min. Moreover, the aptamer-based biosensor showed good specificity toward different unspecific proteins.
en
dc.language.iso
en
-
dc.relation.ispartof
Proceedings
-
dc.subject
Graphene
en
dc.subject
aptamer
en
dc.subject
Biosensor
en
dc.subject
MMP2
en
dc.title
Electrochemical Detection of MMP-2 Using Graphene-Based Aptasensor
en
dc.type
Article
en
dc.type
Artikel
de
dc.contributor.affiliation
University of Novi Sad, Serbia
-
dc.contributor.affiliation
University of Novi Sad, Serbia
-
dc.contributor.affiliation
University of Novi Sad, Serbia
-
dc.type.category
Original Research Article
-
tuw.container.volume
97
-
tuw.container.issue
1
-
tuw.journal.peerreviewed
true
-
tuw.peerreviewed
true
-
wb.publication.intCoWork
International Co-publication
-
tuw.researchinfrastructure
Universitäre Service-Einrichtung für Transmissionselektronenmikroskopie
-
tuw.researchTopic.id
M2
-
tuw.researchTopic.id
M1
-
tuw.researchTopic.name
Materials Characterization
-
tuw.researchTopic.name
Surfaces and Interfaces
-
tuw.researchTopic.value
50
-
tuw.researchTopic.value
50
-
dcterms.isPartOf.title
Proceedings
-
tuw.publication.orgunit
E163-03-1 - Forschungsgruppe Cell Chip
-
tuw.publisher.doi
10.3390/proceedings2024097057
-
dc.date.onlinefirst
2024
-
dc.identifier.articleid
57
-
dc.identifier.eissn
2504-3900
-
dc.description.numberOfPages
3
-
tuw.author.orcid
0000-0001-7933-3542
-
tuw.author.orcid
0000-0002-8379-6520
-
tuw.author.orcid
0000-0002-1563-7763
-
tuw.author.orcid
0000-0003-2380-2594
-
wb.sciencebranch
Chemie
-
wb.sciencebranch
Chemische Verfahrenstechnik
-
wb.sciencebranch
Pharmazie, Pharmakologie, Toxikologie
-
wb.sciencebranch.oefos
1040
-
wb.sciencebranch.oefos
2040
-
wb.sciencebranch.oefos
3012
-
wb.sciencebranch.value
60
-
wb.sciencebranch.value
20
-
wb.sciencebranch.value
20
-
item.openairecristype
http://purl.org/coar/resource_type/c_2df8fbb1
-
item.openairetype
research article
-
item.fulltext
no Fulltext
-
item.languageiso639-1
en
-
item.grantfulltext
none
-
item.cerifentitytype
Publications
-
crisitem.author.dept
University of Novi Sad
-
crisitem.author.dept
E163-03-1 - Forschungsgruppe Cell Chip
-
crisitem.author.dept
E610 - Vizerektorat Forschung und Innovation
-
crisitem.author.dept
University of Novi Sad
-
crisitem.author.dept
University of Novi Sad
-
crisitem.author.orcid
0000-0001-7933-3542
-
crisitem.author.orcid
0000-0002-7625-2445
-
crisitem.author.orcid
0000-0002-1563-7763
-
crisitem.author.orcid
0000-0003-2380-2594
-
crisitem.author.parentorg
E163-03 - Forschungsbereich Organische und Biologische Chemie