<div class="csl-bib-body">
<div class="csl-entry">Kaser, S., Bergauer, T., Biguri, A., Birkfellner, W., Hatamikia, S., Hirtl, A., Irmler, C., Kirchmayer, B., & Ulrich-Pur, F. (2023). Extension of the open-source TIGRE toolbox for proton imaging. <i>ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK</i>, <i>33</i>(4), 552–566. https://doi.org/10.1016/j.zemedi.2022.08.005</div>
</div>
-
dc.identifier.issn
0939-3889
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/208371
-
dc.description.abstract
Proton irradiation is a well-established method to treat deep-seated tumors in radio oncology. Usually, an X-ray computed tomography (CT) scan is used for treatment planning. Since proton therapy is based on the precise knowledge of the stopping power describing the energy loss of protons in the patient tissues, the Hounsfield units of the planning CT have to be converted. This conversion introduces range errors in the treatment plan, which could be reduced, if the stopping power values were extracted directly from an image obtained using protons instead of X-rays. Since protons are affected by multiple Coulomb scattering, reconstruction of the 3D stopping power map results in limited image quality if the curved proton path is not considered. This work presents a substantial code extension of the open-source toolbox TIGRE for proton CT (pCT) image reconstruction based on proton radiographs including a curved proton path estimate. The code extension and the reconstruction algorithms are GPU-based, allowing to achieve reconstruction results within minutes. The performance of the pCT code extension was tested with Monte Carlo simulated data using three phantoms (Catphan® high resolution and sensitometry modules and a CIRS patient phantom). In the simulations, ideal and non-ideal conditions for a pCT setup were assumed. The obtained mean absolute percentage error was found to be below 1% and up to 8 lp/cm could be resolved using an idealized setup. These findings demonstrate that the presented code extension to the TIGRE toolbox offers the possibility for other research groups to use a fast and accurate open-source pCT reconstruction.
en
dc.language.iso
en
-
dc.publisher
ELSEVIER
-
dc.relation.ispartof
ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK
-
dc.subject
Humans
en
dc.subject
Image Processing, Computer-Assisted
en
dc.subject
Tomography, X-Ray Computed
en
dc.subject
Radiography
en
dc.subject
Phantoms, Imaging
en
dc.subject
Monte Carlo Method
en
dc.subject
Algorithms
en
dc.subject
GPU-based imaging
en
dc.subject
Iterative image reconstruction
en
dc.subject
Proton computed tomography
en
dc.subject
Proton radiography
en
dc.subject
Protons
en
dc.subject
Proton Therapy
en
dc.title
Extension of the open-source TIGRE toolbox for proton imaging