<div class="csl-entry">van den Broek, J., Keller, S., Goodall, I., Parish-Virtue, K., Bauer-Christoph, C., Fuchs, J., Tsipi, D., Güntner, A. T., Blum, T., Mathurin, J.-C., Steiger, M. G., Shirvani, R., Gössinger, M., Graf, M., Anderhub, P., Z’graggen, D., Hüsser, C., Faigle, B., & Agapios, A. (2024). Handheld methanol detector for beverage analysis: interlaboratory validation. <i>Analytical Methods</i>, <i>16</i>(24), 3859–3866. https://doi.org/10.1039/d4ay00919c</div>
</div>
-
dc.identifier.issn
1759-9660
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/208410
-
dc.description.abstract
Methanol is a toxic alcohol contained in alcoholic beverages as a natural byproduct of fermentation or added intentionally to counterfeits to increase profit. To ensure consumer safety, many countries and the EU have established strict legislation limits for methanol content. Methanol concentration is mostly detected by laboratory instrumentation since mobile devices for routine on-site testing of beverages in distilleries, at border stations or even at home are not available. Here, we validated a handheld methanol detector for beverage analysis in an ISO 5725 interlaboratory trial: a total of 119 measurements were performed by 17 independent participants (distilleries, universities, authorities, and competence centers) from six countries on samples with relevant methanol concentrations (0.1, 1.5 vol%). The detector was based on a microporous separation filter and a nanostructured gas sensor allowing on-site measurement of methanol down to 0.01 vol% (in the liquid) within only 2 min by laymen. The detector showed excellent repeatability (<5.4%), reproducibility (<9.5%) and small bias (<0.012 vol%). Additional measurements on various methanol-spiked alcoholic beverages (whisky, rum, gin, vodka, tequila, port, sherry, liqueur) indicated that the detector is not interfered by environmental temperature and spirit composition, featuring excellent linearity (R² > 0.99) down to methanol concentrations of 0.01 vol%. This device has been recently commercialized (Alivion Spark M-20) with comparable accuracy to the gold-standard gas chromatography and can be readily applied for final product inspection, intake control of raw materials or to identify toxic counterfeit products.
en
dc.language.iso
en
-
dc.publisher
ROYAL SOC CHEMISTRY
-
dc.relation.ispartof
Analytical Methods
-
dc.subject
Reproducibility of Results
en
dc.subject
Food Analysis
en
dc.subject
Laboratories
en
dc.subject
Methanol
en
dc.subject
Alcoholic Beverages
en
dc.title
Handheld methanol detector for beverage analysis: interlaboratory validation