<div class="csl-bib-body">
<div class="csl-entry">Hornof, D. (2025). <i>Coincidence electron microscopy studies on coherent and incoherent cathodoluminescence using Timepix3</i> [Diploma Thesis, Technische Universität Wien]. reposiTUm. https://doi.org/10.34726/hss.2025.130870</div>
</div>
-
dc.identifier.uri
https://doi.org/10.34726/hss.2025.130870
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/215333
-
dc.description
Abweichender Titel nach Übersetzung der Verfasserin/des Verfassers
-
dc.description.abstract
When electrons interact with a material, they can induce the emission of light—a phenomenon known as cathodoluminescence (CL). This emitted light may originate either directly from the electron impact or through intermediate processes, classified as coherent or incoherent CL. A primary distinction between these mechanisms lies in the temporal delay between the electron-matter interaction and subsequent photon emission. Additionally, the underlying excitation processes may be distinguished by detecting electron-photon coincidences using advanced time-resolved sensor technology, such as detectors capable of registering single-particle events with nanosecond precision. In this Master's thesis, a coincidence measurement setup using a Timepix3 camera and single-photon counting modules is presented in a transmission electron microscope (TEM). A statistical evaluation method for analyzing time differences between electron-photon pairs is introduced to reveal and interpret temporal correlations. Finally, the experimental setup is tested on a silicon membrane and a micro diamond containing silicon vacancy centres to study electron-photon correlations in coherent and incoherent cathodoluminescence.
en
dc.language
English
-
dc.language.iso
en
-
dc.rights.uri
http://rightsstatements.org/vocab/InC/1.0/
-
dc.subject
Transmissionselektronenmikroskopie
de
dc.subject
Kathodolumineszenz
de
dc.subject
Transmission electron microscopy
en
dc.subject
Cathodoluminescence
en
dc.title
Coincidence electron microscopy studies on coherent and incoherent cathodoluminescence using Timepix3
en
dc.title.alternative
Koinzidenz-Elektronenmikroskopie zur Untersuchung von kohärenter und inkohärenter Kathodolumineszenz mit einer Timepix3 Elektronenkamera
de
dc.type
Thesis
en
dc.type
Hochschulschrift
de
dc.rights.license
In Copyright
en
dc.rights.license
Urheberrechtsschutz
de
dc.identifier.doi
10.34726/hss.2025.130870
-
dc.contributor.affiliation
TU Wien, Österreich
-
dc.rights.holder
Dominik Hornof
-
dc.publisher.place
Wien
-
tuw.version
vor
-
tuw.thesisinformation
Technische Universität Wien
-
tuw.publication.orgunit
E141 - Atominstitut
-
dc.type.qualificationlevel
Diploma
-
dc.identifier.libraryid
AC17516225
-
dc.description.numberOfPages
50
-
dc.thesistype
Diplomarbeit
de
dc.thesistype
Diploma Thesis
en
tuw.author.orcid
0009-0007-8858-5726
-
dc.rights.identifier
In Copyright
en
dc.rights.identifier
Urheberrechtsschutz
de
tuw.advisor.staffStatus
staff
-
item.languageiso639-1
en
-
item.grantfulltext
open
-
item.openairetype
master thesis
-
item.openaccessfulltext
Open Access
-
item.mimetype
application/pdf
-
item.openairecristype
http://purl.org/coar/resource_type/c_bdcc
-
item.cerifentitytype
Publications
-
item.fulltext
with Fulltext
-
crisitem.author.dept
E141-02 - Forschungsbereich Atom Physics and Quantum Optics