<div class="csl-bib-body">
<div class="csl-entry">Teplitchi-Menou, L. (2025). <i>Viscoelastic behavior of fibrin scaffolds under static and cyclic loading : toward optimized mechanical stimulation in tendon bioreactor</i> [Diploma Thesis, Technische Universität Wien]. reposiTUm. https://doi.org/10.34726/hss.2025.134645</div>
</div>
-
dc.identifier.uri
https://doi.org/10.34726/hss.2025.134645
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/218230
-
dc.description
Abweichender Titel nach Übersetzung der Verfasserin/des Verfassers
-
dc.description.abstract
Tendon tissue engineering (TE) offers a promising approach to tackle the weak healing capacity of tendons. In this context, bioreactors play a key role, as they enable the application of controlled mechanical stimulation on the tendon constructs. The MagneTissue bioreactor, designed for ring-shaped scaffolds, is used to mechanically stimulate fibrin-based tendon constructs, which have been seeded with tendon progenitor cells. Cyclic and static stimulation protocols of the tendon constructs are evaluated to determine the impact of loading inputs. However, the viscoelastic properties of the fibrin scaffolds used as a scaffold biomaterial are poorly understood, which may influence mechanical input transmission.This thesis aims to characterize the viscoelastic properties of fibrin ring-shaped scaffolds and assess whether mechanical protocols in the MagneTissue bioreactor can be adapted accordingly. Stress relaxation and creep tests were performed for 30 minutes under static and cyclic loading conditions, replicating the bioreactor environment. A viscoelastic model using a generalized Maxwell formulation with Prony series was developed from the stress relaxation data and used to predict the creep behavior of the fibrin scaffolds. Finally,micro-CT imaging assessed scaffold geometry.The results showed that under both static and cyclic loading, fibrin rings exhibited a significant stress relaxation, approximately 20%. The relaxation profile could be divided into 2 phases: a quick relaxation within the first minute and a slower phase lasting approximately 15 minutes. The Prony series model effectively described the stress relaxation behavior but failed to predict the creep response. This highlights the challenge of predicting a general viscoelastic behavior. The experimental results showed high variability,which did not correlate with ring geometry. Instead, batch-to-batch variability suggests that intrinsic scaffold properties are the main source. This variability in viscoelastic behavior should be considered when analyzing fibrin-based tendon constructs.Although the fibrin scaffolds in the MagneTissue bioreactor were the main focus of this research, a more general statement was identified: in order to provide physiologically meaningful and reliable mechanical inputs, mechanical stimulation in tendon TE must be adapted to scaffold-specific behavior.
en
dc.language
English
-
dc.language.iso
en
-
dc.rights.uri
http://rightsstatements.org/vocab/InC/1.0/
-
dc.subject
Biomechanik
de
dc.subject
Zellträger
de
dc.subject
Fibrin
de
dc.subject
Sehne
de
dc.subject
Biomechanics
en
dc.subject
Cell Scaffold
en
dc.subject
Fibrin
en
dc.subject
Tendon
en
dc.title
Viscoelastic behavior of fibrin scaffolds under static and cyclic loading : toward optimized mechanical stimulation in tendon bioreactor
en
dc.title.alternative
Charakterisierug der Viskoelastizität von Fibrin Zellträgern für optimierte mechanische Stimulation in einem Bioreaktor
de
dc.type
Thesis
en
dc.type
Hochschulschrift
de
dc.rights.license
In Copyright
en
dc.rights.license
Urheberrechtsschutz
de
dc.identifier.doi
10.34726/hss.2025.134645
-
dc.contributor.affiliation
TU Wien, Österreich
-
dc.rights.holder
Lune Teplitchi-Menou
-
dc.publisher.place
Wien
-
tuw.version
vor
-
tuw.thesisinformation
Technische Universität Wien
-
dc.contributor.assistant
Groß, Felix Sebastian
-
tuw.publication.orgunit
E317 - Institut für Leichtbau und Struktur-Biomechanik