<div class="csl-bib-body">
<div class="csl-entry">Silva-Henao, J. D., Pahr, D. H., & Reisinger, A. G. (2025). Predicting osteosynthesis screw failure by peri-implant bone morphology in multiple loading conditions. <i>Journal of the Mechanical Behavior of Biomedical Materials</i>, <i>168</i>, Article 107043. https://doi.org/10.1016/j.jmbbm.2025.107043</div>
</div>
-
dc.identifier.issn
1751-6161
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/222360
-
dc.description.abstract
Osteosynthesis screws are critical in orthopaedic surgery for stabilizing and aligning bone fracture fragments. Despite their importance, screw failure remains a significant complication, often due to excessive movement at the implant-bone interface resulting from both physiological loading and external mechanical forces. This study aims to enhance understanding of screw failure mechanisms by investigating the relationship between peri-implant CT-based trabecular bone morphology and screw failure under axial-, shear-, and mixed loading conditions, including the effect of plate elevation. Using high-resolution micro-computed tomography (micro-CT) and mechanical testing, 100 porcine epiphyseal bone samples were extracted and analysed to measure key CT-based trabecular morphometric indices and correlate them with mechanical failure. The study tested screws under ten different loading configurations. Statistical analyses revealed that bone volume (BV) and bone volume over total volume (BV/TV) are strong predictors of screw failure force, explaining 70-90 % of the variance in failure forces across different loading scenarios. The findings suggest that BV and BV/TV can be used to determine optimal screw implantation sites based on local bone morphology, potentially improving surgical outcomes and reducing postoperative complications. This research contributes to a more comprehensive understanding of orthopaedic screw behaviour and offers a predictive model for clinical use.
en
dc.language.iso
en
-
dc.publisher
ELSEVIER
-
dc.relation.ispartof
Journal of the Mechanical Behavior of Biomedical Materials
-
dc.rights.uri
http://creativecommons.org/licenses/by/4.0/
-
dc.subject
Animals
en
dc.subject
Swine
en
dc.subject
X-Ray Microtomography
en
dc.subject
Weight-Bearing
en
dc.subject
Biomechanical Phenomena
en
dc.subject
Stress, Mechanical
en
dc.subject
Bone morphology
en
dc.subject
Bone volume fraction (BV/TV)
en
dc.subject
Mechanical testing
en
dc.subject
Micro-CT analysis
en
dc.subject
Orthopaedic implants
en
dc.subject
Osteosynthesis screws
en
dc.subject
Predictive modelling
en
dc.subject
Screw failure
en
dc.subject
Bone Screws
en
dc.subject
Materials Testing
en
dc.subject
Fracture Fixation, Internal
en
dc.title
Predicting osteosynthesis screw failure by peri-implant bone morphology in multiple loading conditions