<div class="csl-bib-body">
<div class="csl-entry">Fischer, B. A. (2026). <i>Numerical Investigation of the Buoyancy-Induced Separation of a Plane Laminar Mixed Convection Flow along a Vertical Plate</i> [Diploma Thesis, Technische Universität Wien]. reposiTUm. https://doi.org/10.34726/hss.2026.134706</div>
</div>
-
dc.identifier.uri
https://doi.org/10.34726/hss.2026.134706
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/232773
-
dc.description
Arbeit an der Bibliothek noch nicht eingelangt - Daten nicht geprüft
-
dc.description
Abweichender Titel nach Übersetzung der Verfasserin/des Verfassers
-
dc.description.abstract
Bei gegenläufiger Mischkonvektion an einer beheizten vertikalen Oberfläche kann entgegenwirkender Auftrieb zur Ablösung der Grenzschicht führen. Dieser Vorgang wird numerisch an einer beidseitig mit konstanter Wärmestromdichte beheizten vertikalen Platte in einem Kanal mit abwärts strömender Luft untersucht. Dazu werden zweidimensionale, zeitabhängige laminare Simulationen mit OpenFOAM unter Verwendung der Boussinesq-Näherung berechnet. Die beiden Anströmfälle entsprechen Re_L = 1600 und Re_L ≈ 733, während der globale Mischkonvektionsparameter ungefähr im Bereich 0.14 ≤ Gr*_L/Re_L^(5/2) ≤ 5.76 liegt. Die Ergebnisse werden mit den Experimenten von Kitamura et al., Wickerns Grenzschichtlösung und der lokalen Ablösungsbeschreibung nach Oswatitsch–Schneider verglichen. Die Simulationen geben das wesentliche experimentelle Verhalten von Wärmeübergang und Ablösung wieder. Eine dauerhafte Ablösung tritt numerisch bei Gr*_L/Re_L^(5/2) ≈ 0.205 und damit bei einem geringeren Verhältnis von natürlicher zu erzwungener Konvektion als im Experiment auf. Mit zunehmendem Auftrieb verlagert sich der Ablösebereich stromaufwärts, und die zunächst weitgehend stationäre Strömung geht in annähernd gegenphasige Schwingungen entlang beider Plattenseiten über, die bei höheren Wärmestromdichten komplexer und asymmetrischer werden. Stromaufwärts der Ablösung stimmen die berechneten Geschwindigkeits- und Temperaturprofile gut mit Wickerns Grenzschichtlösung überein, während sich die skalierten Größen nicht durch die für die halbunendliche Platte geltende Beziehung beschreiben lassen. In der Nähe regulärer Ablösung stimmen die numerischen und analytischen Trennstromlinien, Ablösewinkel und lokalen Temperaturfelder gut überein, wobei größere Abweichungen auftreten, wenn sich der Ablösepunkt dem abgerundeten oberen Plattenende nähert. Insgesamt stimmen die Simulationen dort gut mit den analytischen Beschreibungen überein, wo deren Voraussetzungen erfüllt sind.
de
dc.description.abstract
Opposing mixed convection along a heated vertical surface can cause boundary-layer separation when buoyancy acts against a downward forced flow. This process is investigated numerically for a vertical plate heated on both sides by a constant wall heat flux in a duct with downward-flowing air, using two-dimensional time-dependent laminar OpenFOAM simulations with the Boussinesq approximation. The two inflow conditions correspond to Re_L = 1600 and Re_L ≈ 733, while the global mixed-convection parameter spans approximately 0.14 ≤ Gr*_L/Re_L^(5/2) ≤ 5.76. The results are compared with experimental data from Kitamura et al., Wickern's vertical-plate boundary-layer solution, and the local Oswatitsch–Schneider separation description. The simulations reproduce the main experimental heat-transfer and separation behaviour. Sustained separation is detected numerically at Gr*_L/Re_L^(5/2) ≈ 0.205, at a lower relative natural-convection strength than in the experiments. Increasing opposing buoyancy moves the separation region upstream and changes the flow from an essentially steady state to approximately anti-phase oscillations along the two plate sides, which become more complex and asymmetric at higher wall heat fluxes. The upstream velocity and temperature profiles agree closely with Wickern's boundary-layer solution, whereas the scaled wall quantities do not collapse onto the semi-infinite-plate relation. Near regular separation, the numerical and analytical dividing streamlines, separation angles, and local temperature fields show close agreement, with larger deviations when the separation point approaches the rounded upper plate end. Overall, the simulations reproduce the principal experimental behaviour and show close agreement with the analytical descriptions where their assumptions are best satisfied.
en
dc.language
English
-
dc.language.iso
en
-
dc.rights.uri
http://rightsstatements.org/vocab/InC/1.0/
-
dc.subject
Mischkonvektion
de
dc.subject
Strömungsablösung
de
dc.subject
Grenzschicht
de
dc.subject
Auftrieb
de
dc.subject
laminare Strömung
de
dc.subject
inkompressible Strömung
de
dc.subject
CFD
de
dc.subject
mixed convection
en
dc.subject
flow separation
en
dc.subject
boundary layer
en
dc.subject
buoyancy
en
dc.subject
laminar flow
en
dc.subject
incompressible flow
en
dc.subject
CFD
en
dc.title
Numerical Investigation of the Buoyancy-Induced Separation of a Plane Laminar Mixed Convection Flow along a Vertical Plate
en
dc.title.alternative
Numerische Untersuchung der auftriebsbedingten Ablösung einer ebenen laminaren Mischkonvektionsströmung an einer vertikalen Platte
de
dc.type
Thesis
en
dc.type
Hochschulschrift
de
dc.rights.license
In Copyright
en
dc.rights.license
Urheberrechtsschutz
de
dc.identifier.doi
10.34726/hss.2026.134706
-
dc.contributor.affiliation
TU Wien, Österreich
-
dc.rights.holder
Benedikt Anton Fischer
-
dc.publisher.place
Wien
-
tuw.version
vor
-
tuw.thesisinformation
Technische Universität Wien
-
dc.contributor.assistant
Babor, Lukas
-
tuw.publication.orgunit
E322 - Institut für Strömungsmechanik und Wärmeübertragung