<div class="csl-entry">Riedlsperger, L., Schwaighofer, A., Lendl, B., & Ramer, G. (2026, May 5). <i>Chemometric Calibration of Laser-based Mid-IR Spectroscopy for Real-Time Biopharmaceutical Process Monitoring</i> [Poster Presentation]. 7th European Conference on Process Analytics and Control Technology (EuroPACT 2026), Lyon, France.</div>
</div>
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/232866
-
dc.description.abstract
The transition towards continuous processing in the pharmaceutical industry induces the need of process analytical technology (PAT) that are capable of real-time monitoring and control of critical quality attributes such as the protein folding, aggregation and fragmentation. However, as of today, only slow, off-line or not fit for purpose techniques exist. Mid-infrared (mid-IR) spectroscopy has established itself as a promising PAT tool capable of directly accessing complex process parameters and critical quality attributes across various biopharmaceutical applications such as monoclonal antibody production.
Laser-based mid-IR analysis of monoclonal antibodies Mid-IR spectroscopy is widely used in the PAT field for its ability to provide rapid, non destructive analysis. Proteins display distinct absorption bands arising from the peptide
backbone and specific amino acid side chains. The characteristic band maxima and shapes of the amide I band (1600-1700 cm-1) and to a lesser degree the amide II band (1500-1600 cm-1) are of particular interest since they contain information about the secondary structure of the protein. Analysis of the amide bands therefore enables
characterization of proteins and detection of aggregation or misfolding. However, due to the high absorbance of aqueous solvents, the optimal transmission pathlengths for conventional FTIR spectrometers are extremely short (around 8 μm). External cavity quantum cascade lasers (EC-QCLs) are broadly tunable mid-IR light sources that offer spectral power density several orders of magnitude higher than those of conventional FTIR instruments. This enables the use of greater optical pathlengths (> 20 µm) and makes mid-IR spectroscopy fit for purpose for flow-through measurements in PAT settings.
Chemometric Background Subtraction: For applications in the downstream process of monoclonal antibodies, the challenge lies in the complex and evolving matrices of the production as there is typically a constant change of buffer composition, pH and temperature. As a result, conventional baseline correction and smoothing are insufficient and may mask chemically relevant information. We therefore present a chemometric calibration framework based on Multivariate Curve Resolution - Alternating Least Squares (MCR-ALS) to resolve the
background spectra of the specific buffer components. Auxiliary process information such as pH and conductivity are taken into account as hard-modelling tools. We show that the quantum cascade laser based spectroscopic setup combined with informed chemometric background recovery, is a promising route toward real‑time PAT
solutions in biopharmaceutical manufacturing.
en
dc.description.sponsorship
Christian Doppler Forschungsgesells
-
dc.language.iso
en
-
dc.subject
EC-QCL
en
dc.subject
Chemometrics
en
dc.subject
Protein-Analysis
en
dc.title
Chemometric Calibration of Laser-based Mid-IR Spectroscopy for Real-Time Biopharmaceutical Process Monitoring
en
dc.type
Presentation
en
dc.type
Vortrag
de
dc.relation.grantno
Fortgeschrittene MIR Laserspektroskopie
-
dc.type.category
Poster Presentation
-
tuw.project.title
Christian Doppler Labor für Fortgeschrittene MIR Laserspektroskopie in der (Bio-)prozessanalytik
-
tuw.researchTopic.id
M2
-
tuw.researchTopic.id
X1
-
tuw.researchTopic.id
I8
-
tuw.researchTopic.name
Materials Characterization
-
tuw.researchTopic.name
Beyond TUW-research focus
-
tuw.researchTopic.name
Sensor Systems
-
tuw.researchTopic.value
50
-
tuw.researchTopic.value
30
-
tuw.researchTopic.value
20
-
tuw.publication.orgunit
E164-02-1 - Forschungsgruppe Prozessanalytik
-
tuw.publication.orgunit
E056-04 - Fachbereich TU-DX: Towards Applications of 2D Materials
-
tuw.publication.orgunit
E056-12 - Fachbereich ENROL DP
-
tuw.author.orcid
0009-0009-7577-4397
-
tuw.author.orcid
0000-0003-2714-7056
-
tuw.author.orcid
0000-0003-3838-5842
-
tuw.author.orcid
0000-0001-8307-5435
-
tuw.event.name
7th European Conference on Process Analytics and Control Technology (EuroPACT 2026)
en
tuw.event.startdate
04-05-2026
-
tuw.event.enddate
07-05-2026
-
tuw.event.online
On Site
-
tuw.event.type
Event for scientific audience
-
tuw.event.place
Lyon
-
tuw.event.country
FR
-
tuw.event.presenter
Riedlsperger, Lisa
-
tuw.event.track
Multi Track
-
wb.sciencebranch
Chemie
-
wb.sciencebranch.oefos
1040
-
wb.sciencebranch.value
100
-
item.fulltext
no Fulltext
-
item.grantfulltext
restricted
-
item.languageiso639-1
en
-
item.openairecristype
http://purl.org/coar/resource_type/c_18co
-
item.openairetype
conference poster not in proceedings
-
item.cerifentitytype
Publications
-
crisitem.project.funder
Christian Doppler Forschungsgesells
-
crisitem.project.grantno
Fortgeschrittene MIR Laserspektroskopie
-
crisitem.author.dept
E164-02-1 - Forschungsgruppe Prozessanalytik
-
crisitem.author.dept
E164-02-1 - Forschungsgruppe Prozessanalytik
-
crisitem.author.dept
E164-02 - Forschungsbereich Umwelt-, Prozessanalytik und Sensoren
-
crisitem.author.dept
E164-02-1 - Forschungsgruppe Prozessanalytik
-
crisitem.author.orcid
0009-0009-7577-4397
-
crisitem.author.orcid
0000-0003-2714-7056
-
crisitem.author.orcid
0000-0003-3838-5842
-
crisitem.author.orcid
0000-0001-8307-5435
-
crisitem.author.parentorg
E164-02 - Forschungsbereich Umwelt-, Prozessanalytik und Sensoren
-
crisitem.author.parentorg
E164-02 - Forschungsbereich Umwelt-, Prozessanalytik und Sensoren
-
crisitem.author.parentorg
E164 - Institut für Chemische Technologien und Analytik
-
crisitem.author.parentorg
E164-02 - Forschungsbereich Umwelt-, Prozessanalytik und Sensoren