<div class="csl-bib-body">
<div class="csl-entry">Contawe, C. (2017). <i>Comparison of manually and automatically derived ECG-based left ventricular hypertrophy parameters and their predictive value in survival analysis</i> [Diploma Thesis, Technische Universität Wien]. reposiTUm. https://doi.org/10.34726/hss.2017.37337</div>
</div>
-
dc.identifier.uri
https://doi.org/10.34726/hss.2017.37337
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/3801
-
dc.description
Zusammenfassung in deutscher Sprache
-
dc.description
Abweichender Titel nach Übersetzung der Verfasserin/des Verfassers
-
dc.description.abstract
The presence of left ventricular hypertrophy (LVH) is linked to high risk of cardiovascular mortality, especially in dialysis patients. With the knowledge that LVH is reversible, an accurate method of detection in this cohort would be invaluable. Electrocardiography (ECG) is an universal, inexpensive procedure done at most healthcare settings. It is of great interest to further develop and improve ECG-based LVH parameters for assessing LVH incidence. The standard procedure for determining the parameters is to derive them from manual measurements of the electrocardiogram. Manual measurements are subject to human error and time consuming, thus it would advantageous to develop automatic methods of computing ECG-based LVH parameters. The aim of this thesis is to develop an automatic method of calculating the parameters and compare the results with manual measurements done by an experienced physician. Furthermore, the results, in combination with follow-up data, will be assessed for their predictive value in survival analysis. Four parameters were chosen to be automatically compared, the Sokolow-Lyon Voltage (SLV), the Cornell Voltage (CV), the Cornell Voltage Product (CVP), and the Novacode estimate. The AIT ECGsolver and QRS detectors taken from PhysioNet were used for detection of ECG waveforms and features. An algorithm was developed to compute the criteria by automatically evaluating amplitudes and intervals on a subset of 335 patients of the ISAR study. Recommended thresholds were applied to convert the calculated variables into dichotomized measurements. Both the criteria results and the threshold outcomes were compared with the manually derived matched beat measurements annotated by the physician. The voltage dependent criteria, SLV, CV, and the female Novacode estimate, demonstrated very good agreement between the two methods, both in measurements and LVH outcome. McNemar's test for these criteria showed no statistically significant difference between the measurement methods based on the dichotomized outcomes. Consistent overestimation of the QRS interval by automatic methods in comparison to the manual method proved to be problematic. The CVP and male Novacode are both dependent on QRS duration and demonstrated less agreement between the method measurements. McNemar¿s test showed for the male Novacode that there is a statistically significant difference between the methods, but not for the CVP. Interestingly, the survival analysis showed that CV, CVP, and the automatically derived Novacode were statistically significant risk predictors for all-cause mortality. This is in contrast to published studies which report no significant LVH criteria for all-cause mortality. Automatic methods of parameter calculation proved to be useful, but with limitations. Improvements in QRS interval detection would greatly refine the method. Future opportunities to expand the work done in this thesis would be a comparison of the binary results with accurate left ventricular mass (LVM) measurements, a repeat of the work during known dialysis treatment times (dialysis versus non-dialysis), and a recomparison using a standard method of manual QRS interval measurement.
en
dc.language
English
-
dc.language.iso
en
-
dc.rights.uri
http://rightsstatements.org/vocab/InC/1.0/
-
dc.subject
Automatische Auswertung und Verifikation
de
dc.subject
EKG
de
dc.subject
Linksventrikuläre Hypertrophie
de
dc.subject
Automatic detection and verification
en
dc.subject
ECG
en
dc.subject
Left Ventricular Hypertrophy
en
dc.title
Comparison of manually and automatically derived ECG-based left ventricular hypertrophy parameters and their predictive value in survival analysis
en
dc.title.alternative
Verifikation von Algorithmen zur automatischen Bestimmung von EKG-basierten Parametern zur Detektion von linksventrikulärer Hypertrophie und deren klinische Aussagekraft in Survival-Analysen
de
dc.type
Thesis
en
dc.type
Hochschulschrift
de
dc.rights.license
In Copyright
en
dc.rights.license
Urheberrechtsschutz
de
dc.identifier.doi
10.34726/hss.2017.37337
-
dc.contributor.affiliation
TU Wien, Österreich
-
dc.rights.holder
Corina Contawe
-
dc.publisher.place
Wien
-
tuw.version
vor
-
tuw.thesisinformation
Technische Universität Wien
-
dc.contributor.assistant
Mayer, Christopher
-
tuw.publication.orgunit
E354 - Institute of Electrodynamics, Microwave and Circuit Engineering