Title: Neutronenstreulängenmessung mit Christiansenfilter im Neutroneninterferometer
Other Titles: Messuring of neutron scattering length with Christiansen-filter in neutron interferometer
Language: Deutsch
Authors: Schroffenegger, Juri
Qualification level: Diploma
Advisor: Rauch, Helmut
Assisting Advisor: Jericha, Erwin 
Issue Date: 2011
Number of Pages: 68
Qualification level: Diploma
Abstract: 
Um die kohärenten Streulängen bc der zu untersuchenden isotopenreinen Stoffe zu bestimmen, wird ein Christiansenfilter in einen der Teilstrahlen eines schiefsymmetrischen Neutroneninterferometers eingebracht. Das Christiansenfilter besteht im Wesentlichen aus einer Quarzglas-Küvette, die mit einer Mischung aus H2O und D2O sowie dem in fester Form vorliegenden Probenmaterial befüllt ist. Unterscheidet sich die Streulängendichte (〖Nb〗_C )_F der Flüssigkeitsmatrix von jener der Probe〖 (〖Nb〗_C )〗_P, tritt für die sich im Filter befindenden Neutronen Kleinwinkelstreuung auf. Diese gestreuten Neutronen können bei der Zusammenführung der beiden Teilstrahlen des Interferometers nicht mehr zur Interferenz beitragen.
Dies führt zu einer Verminderung des Kontrasts im Interferenzbild. Für einen Abgleich der Streulängen (〖Nb〗_C )_F=(〖Nb〗_C )_P tritt keine Streuung auf und der Kontrast wird maximal. Ist die Streulängendichte der Flüssigkeitsmatrix bekannt, lässt sich so jene des Probenmaterials und so auch die Streulänge selbst bestimmen. Die so ermittelten Streulängen sind:
206Pb: bc=9,227±0,042fm 207Pb: bc=9,442±0,031fm 108Pd: bc=4,321±0,071fm

To determine the coherent scattering lengths bc of the materials of interest, a Christiansen-filter is installed into a skew-symmetric neutron-interferometer. The Christiansen-filter is composed by a fused quartz glass cell, filled with a mixture of H2O and D2O and the sample material in solid state. Small angle scattering appears for the neutrons in the filter, in case the scatting lengths density of the liquid (Nb_c )_(F )differs from the one of the sample〖 (Nb_c )〗_P. At the conjunction point of both semi-rays of the interferometer, the scattered neutrons cannot contribute to the interference. This leads to a reduction of the contrast in the picture of interference. With equal scattering lengths (Nb_c )_F=(Nb_c )_P no scattering will appear and the contrast is at its maximum. If the scattering length density of the liquid is known, the one of the sample can be determined and so can the scattering length itself.
The following scatter lengths were measured:
206Pb: bc=9,227±0,042fm 207Pb: bc=9,442±0,031fm 108Pd: bc=4,321±0,071fm
Keywords: Neutronenstreulänge; Christiansenfilter; Interferomerter
neutron scattering length; Christiansen-filter; interferometer
URI: https://resolver.obvsg.at/urn:nbn:at:at-ubtuw:1-42763
http://hdl.handle.net/20.500.12708/11930
Library ID: AC07810199
Organisation: E141 - Atominstitut 
Publication Type: Thesis
Hochschulschrift
Appears in Collections:Thesis

Files in this item:

Show full item record

Page view(s)

5
checked on Jun 11, 2021

Download(s)

72
checked on Jun 11, 2021

Google ScholarTM

Check


Items in reposiTUm are protected by copyright, with all rights reserved, unless otherwise indicated.