Baumgartner, L. (2024). Integrated linear optical receiver for MRI coil signals [Diploma Thesis, Technische Universität Wien]. reposiTUm. https://doi.org/10.34726/hss.2024.116761
E354 - Institute of Electrodynamics, Microwave and Circuit Engineering
-
Date (published):
2024
-
Number of Pages:
67
-
Keywords:
Optischer Empfänger; integrierte Schaltungen; MRT
de
Optical receiver; integrated circuits; MRI
en
Abstract:
This thesis illustrates the design of an opto electronic integrated circuit (OEIC),applicable as an optical receiver for magnetic resonance imaging (MRI) coil signals. It is intended for the use of the receiver part of an optical wireless communication (OWC) system within a MRI with a maximum desired optical input power of 1mW to mitigate electromagnetic interference (EMI) problems of receiving coil assemblies. The novelty is to use an optical free space laser beam within the MRI environment for transferring signals gather from the receive coils. The chip is realized in a 0.35 μm complementary metal-oxide-semiconductor (CMOS) process. It produces an appropriate voltage signal within approximately −500mV and 500mV at the output after external AC coupling. At the beginning various wireless communication techniques are explained and compared. Based on the proposed circuit topology and process technology, countless simulations were carried out to get a superior design with the imposed constrains within the quite restricted amount of time. Post layout simulations result in a nominal total harmonic distortion (THD) rate of 1.101% at the frequency of interest, which is 123 MHz. Furthermore, the bandwidth of chip ranges up to approximately 1GHz.