<div class="csl-bib-body">
<div class="csl-entry">Estermann, S.-J. (2017). <i>Investigation of fluid flow-induced stimulation of osteocytes by means of micromechanics-inspired multiscale modeling</i> [Diploma Thesis, Technische Universität Wien]. reposiTUm. https://doi.org/10.34726/hss.2017.41100</div>
</div>
-
dc.identifier.uri
https://doi.org/10.34726/hss.2017.41100
-
dc.identifier.uri
http://hdl.handle.net/20.500.12708/5097
-
dc.description
Zusammenfassung in deutscher Sprache
-
dc.description.abstract
Unter all den Theorien, die die mechanische Zellstimulation betreffen, ist der vermeintliche Effekt der Flüssigkeitsströmung im Porennetzwerk aus Lakunen und Canaliculi hinsichtlich der Anregung von Osteozyten der in Wissenschaftskreisen oftmals anerkannteste. Es war bisher allerdings nicht möglich, diese Strömungen in vivo zu messen und derart die zugrundeliegenden Hypothese zu bestätigen. In dieser Diplomarbeit wird eine Modellierungsmethode vorgestellt, die dem Multiskalen-Paradigma folgt und auf den Prinzipien der Kontinuumsmikromechanik aufgebaut ist. Dieses Modell erlaubt einerseits die Berechnung (bzw. die Homogenisierung) der entsprechenden makroskopischen Permeabilität von Knochengewebe, ausgehend von den Beiträgen (die Flüssigkeitsströmung betreffend) der canaliculären, lakunaren und vaskulären Porenräume. Andererseits ermöglicht das Model auch eine umgekehrte Vorgehensweise, d.h. das "Runterskalieren'' (oder "Downscaling''), bei dem die Druckgradienten in den Porenräumen berechnet werden, ausgehend von den makroskopisch aufgebrachte Druckgradienten. In weiterer Folge können durch die Berücksichtigung der so ermittelten lokalen Druckgradienten in geeigneten Transportgesetzen (wie z.B. im Flussgesetz nach Poiseuille) die Geschwindigkeiten von Flüssigkeitsströmen in den canaliculären Poren berechnet werden. Der Vergleich zwischen den so berechneten Flussgeschwindigkeiten (für kortikalen Knochen) und den Geschwindigkeiten, die Knochenzellen in vitro stimulieren, zeigt, dass die hier gefundenen Geschwindigkeiten viel zu niedrig sind um Zellen ausreichend zu stimulieren. Daraus folgt, dass, laut dem hier vorgestellten Modell, die Stimulation von Osteozyten durch Flüssigkeitsströmung vermutlich kein effektiver Mechanismus in der Mechanobiologie von Knochengewebe ist (wohingegen die Zellen, welche sich im vaskulären Porenraum befinden, sehr wohl ausreichend schnellen Flüssigkeitsströmen ausgesetzt sind). Folglich liefert die hier präsentierte Arbeit einen entscheidenden Beitrag zur Beleuchtung der zellulären Mechnostimulation auf unterschiedlichen Größenskalen in Knochen.
de
dc.description.abstract
Of all the theories related to the mechanical excitation of cellular activities, the alleged effect of the fluid flow occurring in the lacunar-canalicular pore network on osteocytes is probably the most widely accepted. However, direct experimental verification of the actual occurrence of fluid flow (in response to macroscopically applied mechanical loading of physiologically reasonable magnitude) in these pores has never been obtained. In this work, a multiscale modeling strategy is presented, inspired by the well-established concept of continuum micromechanics, allowing for upscaling (or homogenization) of the fluid flow contributions in the canalicular, lacunar, and vascular pores in terms of a corresponding macroscopic permeability of bone tissue. The same model also allows for proceeding the opposite way, namely for downscaling macroscopically acting pressure gradients to the pore levels. Thus, physiologically relevant, macroscopic pressure gradients can be related straightforwardly to the correspondingly arising canalicular pressure gradients, and, through considering the resulting pressure gradients in suitable transport laws (as for instance the classical Poiseuille law on the canalicular level), also to related fluid velocities. When comparing the such computed fluid velocities (for cortical bone) with the fluid velocities that were shown to efficiently excite bone cells , it turns out that the fluid velocities according to the here presented computations are actually much lower. This implies that, based on the multiscale model, pressure-driven fluid flow in the canalicular pores is not likely to be a potent mechanical stimulus for osteocytes (whereas fluid flow in the vascular pores may indeed reach the required fluid velocities and hence excite the therein residing cells). In conclusion, the work presented in this thesis provides important, unprecedented insights as to the observation scale-specific cellular mechanosensation in bone.
en
dc.language
English
-
dc.language.iso
en
-
dc.rights.uri
http://rightsstatements.org/vocab/InC/1.0/
-
dc.subject
fluid flow-induced stimulation
de
dc.subject
fluid flow-induced stimulation
en
dc.title
Investigation of fluid flow-induced stimulation of osteocytes by means of micromechanics-inspired multiscale modeling
en
dc.title.alternative
Untersuchung der Stimulation von Osteozyten durch Flüssigkeitsströmung durch Multiskalenmodellierung, basierend auf Prinzipien der Mikromechanik
de
dc.type
Thesis
en
dc.type
Hochschulschrift
de
dc.rights.license
In Copyright
en
dc.rights.license
Urheberrechtsschutz
de
dc.identifier.doi
10.34726/hss.2017.41100
-
dc.contributor.affiliation
TU Wien, Österreich
-
dc.rights.holder
Sarah-Jane Estermann
-
dc.publisher.place
Wien
-
tuw.version
vor
-
tuw.thesisinformation
Technische Universität Wien
-
dc.contributor.assistant
Scheiner, Stefan
-
tuw.publication.orgunit
E202 - Institut für Mechanik der Werkstoffe und Strukturen