Title: An exploration of the thermal performance of office buildings in Ghana
Language: English
Authors: Koranteng, Christian 
Qualification level: Doctoral
Advisor: Mahdavi, Ardeshir
Assisting Advisor: Ilal, Emre 
Kühn, Christian 
Issue Date: 2010
Number of Pages: 212
Qualification level: Doctoral
Abstract: 
Diese Dissertation präsentiert die Ergebnisse einer Langzeitbeobachtung der thermischen Bedingungen in ausgewählten Bürogebäuden in Kumasi, Ghana. Die gesammelten Daten wurden nicht nur verwendet um die Innenraum Bedingungen der Büros zu bewerten, sondern auch um einige Simulationsmodelle zu kalibrieren. So konnte eine auf Simulationen basierte Erforschung der Nachrüstungsmassnahmen zum Zwecke einer generellen Reduktion des Kühlungsbedarfs durchgeführt werden.
Ausserdem wurden die Auswirkungen der Nachrüstungsmassnahmen zur Reduzierung des CO2 Ausstosses bewertet und die Amortisationszeiten für Investitionen in derartige Massnahmen geschätzt. Die Ergebnisse zeigen, dass Verbesserungen am Gebäude (mit Rückzahlungszeiten von 3 bis 12 Jahren) die Kühllast am Gebäude um 20 bis 35% reduzieren können, und den CO2 Ausstoss um etwa 27%. Das Ergebnis der geführten Interviews zeigte, dass 45% bzw. 70% der BewohnerInnen in gemischt (klimatisiert und natürlich belüftet) thermisch kontrollierten Gebäuden bzw in natürlich belüfteten Gebäuden, unzufrieden waren mit der Luftqualität während der Trockenzeit. Die höchste Unzufriedenheit mit dem Innenraumklima wurde von 85% der BewohnerInnen im natürlich belüfteten Gebäude ausgedrückt.
Eine relativ hohe Wichtigkeit (55% bis 80%) wurde der Bedienung der Fenster und Fensterläden zugesprochen, abhängig von der Art des Gebäudes.

This dissertation comprises the outcome of a long-term monitoring of the thermal conditions in a selected number of office buildings in Kumasi, Ghana. The observed data was not only used to assess indoor environmental conditions in these offices, but also to calibrate a number of thermal simulation models of the buildings. Thus, a simulation-based exploration of thermal retrofit options toward a general reduction of cooling requirements could be conducted. Moreover, the impact of thermal retrofit measures toward reducing carbon dioxide (CO2) emissions was assessed and the amortization times for investments in such retrofit measures were estimated. The results suggest that improvements in building fabric and controls (with payback times of 3 to 12 years) can reduce buildings' cooling loads by around 20% to 35% and CO2 emissions around 27%. Additionally, the outcome of interviews conducted showed that 45% and 70% of occupants in mixed-mode and naturally ventilated buildings were uncomfortable with the air quality during the dry season. The highest dissatisfaction with indoor environment was reported by 85% of the occupants in the naturally ventilated building. The importance attached to the operation of windows and shades was relatively high, 55% to 80%, depending on building type
Keywords: Kühllast; Simulation; Energie; Effizienz; Bausysteme; Kontrollsysteme; Psychrometrische Tabelle; Aktiv; Passiv; Umgebung
Cooling loads; simulation; energy; efficiency; building systems; system controls; psychrometric chart; active; passive; environment
URI: https://resolver.obvsg.at/urn:nbn:at:at-ubtuw:1-44709
http://hdl.handle.net/20.500.12708/11619
Library ID: AC07808162
Organisation: E259 - Institut für Architekturwissenschaften 
Publication Type: Thesis
Hochschulschrift
Appears in Collections:Thesis

Files in this item:


Page view(s)

22
checked on Aug 3, 2021

Download(s)

63
checked on Aug 3, 2021

Google ScholarTM

Check


Items in reposiTUm are protected by copyright, with all rights reserved, unless otherwise indicated.