Title: Virus-like particle size and molecular weight/mass determination applying gas-phase electrophoresis (native nES GEMMA)
Language: English
Authors: Weiss, Victor U. 
Pogan, Ronja 
Zoratto, Samuele 
Bond, Kevin M. 
Boulanger, Pascale 
Jarrold, Martin F. 
Lyktey, Nicholas 
Pahl, Dominik 
Puffler, Nicole 
Schelhaas, Mario 
Selivanovitch, Ekaterina 
Uetrecht, Charlotte 
Allmaier, Günter
Category: Research Article
Forschungsartikel
Issue Date: 2019
Journal: Analytical and Bioanalytical Chemistry
ISSN: 1618-2650
Abstract: 
(Bio-)nanoparticle analysis employing a nano-electrospray gas-phase electrophoretic mobility molecular analyzer (native nES GEMMA) also known as nES differential mobility analyzer (nES DMA) is based on surface-dry analyte separation at ambient pressure. Based on electrophoretic principles, single-charged nanoparticles are separated according to their electrophoretic mobility diameter (EMD) corresponding to the particle size for spherical analytes. Subsequently, it is possible to correlate the (bio-)nanoparticle EMDs to their molecular weight (MW) yielding a corresponding fitted curve for an investigated analyte class. Based on such a correlation, (bio-)nanoparticle MW determination via its EMD within one analyte class is possible. Turning our attention to icosahedral, non-enveloped virus-like particles (VLPs), proteinaceous shells, we set up an EMD/MW correlation. We employed native electrospray ionization mass spectrometry (native ESI MS) to obtain MW values of investigated analytes, where possible, after extensive purification. We experienced difficulties in native ESI MS with time-of-flight (ToF) detection to determine MW due to sample inherent characteristics, which was not the case for charge detection (CDMS). nES GEMMA exceeds CDMS in speed of analysis and is likewise less dependent on sample purity and homogeneity. Hence, gas-phase electrophoresis yields calculated MW values in good approximation even when charge resolution was not obtained in native ESI ToF MS. Therefore, both methods-native nES GEMMA-based MW determination via an analyte class inherent EMD/MW correlation and native ESI MS-in the end relate (bio-)nanoparticle MW values. However, they differ significantly in, e.g., ease of instrument operation, sample and analyte handling, or costs of instrumentation.
Keywords: Native nES GEMMA; DMA; VLP; Molecular weight; mass; Size; Mass spectrometry
DOI: 10.1007/s00216-019-01998-6
Library ID: AC15537814
URN: urn:nbn:at:at-ubtuw:3-8119
Organisation: E164 - Institut für Chemische Technologien und Analytik 
Publication Type: Article
Artikel
Appears in Collections:Article

Files in this item:


Page view(s)

80
checked on Jul 26, 2021

Download(s)

104
checked on Jul 26, 2021

Google ScholarTM

Check


This item is licensed under a Creative Commons License Creative Commons